Important: Read these instructions for use carefully so as to familiarize yourself with the appliance
before connecting it to its gas container. Keep these instructions for future reference.
• Turn off gas supply at bottle
• Extinguish all naked flames
• Do not operate any electrical appliances
• Ventilate the area
• Check for leaks as detailed in this manual
If odour persists, contact your dealer or gas supplier immediately.
Do not tamper or modify the appliance.
BURN-BACK (FIRE IN BURNER TUBE OR CHAMBER)
In the event of a burn-back, where the flame burns back to the jet, immediately turn the gas supply
off at the control valve on the panel. After ensuring the flame is extinguished, wait for I minute and
re-light the appliance in the normal manner. Should the appliance again burn back, close the control
valve and call a service technician. Do not use the appliance again until the service technician has
declared that it is safe to do so.
This appliance requires an operating pressure of 2,8 kPa at the appliance. This appliance is set as
NG, a suitable LPG regulator, that complies with the requirements of SANS 1237, must be
installed.
IMPORTANT INFORMATION FOR THE USER
This appliance may only be installed by a registered SAQCC Gas installer. All registered installers
are issued with a card carrying their registration number. Ask to be shown the card before allowing
the installation work to commence and make a note of the Installer registration number. Upon
completion of the installation, the installer is required to explain the operational details of the
appliance together with the safety instructions. You will be asked to sign acceptance of the
installation and be provided with a completion certificate. You should only sign for acceptance of
the installation when the installation is completed to your satisfaction.
Note that your invoice is required in the event that you wish make a guarantee claim.
IMPORTANT INFORMATION FOR THE INSTALLER
This appliance may only be installed by a gas installer registered with the South African qualification
and certification committee (SAQCC). The appliance must be installed in accordance with the
requirements of SANS 10087-1for use with LPG, SANS 827 for use with NG and any fire
department regulations and/or local bylaws applicable to the area. If in doubt, check with the
relevant authority before undertaking the installation. Upon completion of the installation you are
required to fully explain and demonstrate to the user the operational details and safety practices
applicable to the appliance and the installation.
Table of burner and nozzle specifications
Table1 (for Poland)
Burner
Diameter
(mm)
Fast (Large)(R)
100
Semi Fast
75
(Medium)(S)
Auxiliary (Small)(A)
51
Supply Pressures
Additional notes
IF YOU SMELL GAS:
GAS-PRESSURE REGULATOR
NATURAL GAS
(Methane) NG
Thermal
Nozzle
Power
1/100
kPa
(mm)
3,00
128
1,90
104
1,00
78
2,0 kPa
LIQUEFIED GAS
LIQUEFIED GAS (Butane) LPG
Flow*
Thermal
Dysza
l/h
power
1/100
kPa
(mm)
286
3,40
87
181
2,20
69
95
1,10
50
2,8 kPa
Flow*
g/h
247
160
80
35