Electrical Connection Of An External Blower - Miele DA6881EB Operating And Installation Instructions

Downdraft
Table of Contents

Advertisement

Electrical connection
Electrical connection of an
external blower
Disconnect the appliance from the
electrical power supply.
 Install a connection cord from the
downdraft to the external blower.
Refer to the Operating and
Installation Instructions for the
DAG 1000 external blower.
Use the connection box supplied with
the DAG 1000 external blower for
connection to the downdraft.
 Open the cover on the connection
box.
 Remove the cover from the cord
entry, e.g. with the aid of a
screwdriver.
 Install an approved cable clamp or
connector.
 Guide the connection cord from the
external blower into the connection
box.
36
 Connect the power cord. Please
check the enclosed wiring diagram.
 Secure the connection box to a
suitable place, e.g. a cabinet wall.
If moisture gets into the unit, this can
cause an electric shock
Therefore, the connection box must
not be in contact with the floor.
Position and secure the cord and
other connection leads in a suitable
place.
 Connect the power as described
previously.

Advertisement