Appendix B: Parameters - Parker 2003-PB-00 Technical Manual

Profinet io– communication option
Hide thumbs Also See for 2003-PB-00:
Table of Contents

Advertisement

APPENDIX B: Parameters

Function Block Inputs
Parameter Name
No.
COMMS REQUIRED
691
Communications option required.
ADDR ASSIGNMENT
758
Method for assigning the IP address.
SET IP ADDRESS
759
Ethernet option IP address
SET SUBNET MASK
760
Ethernet option subnet mask.
SET GATEWAY ADDR
761
Ethernet option gateway address.
ACCESS
762
Ethernet access using comms option (bitwise)
NODE ADDRESS
763
Communications node address.
CANOPEN BAUD
764
Required baud Rate for CANopen.
MODBUS BAUD RATE
765
Required baud Rate for Modbus RTU
PARITY
766
Modbus parity and stop bits
HIGH WORD FIRST
767
For 32-bit values high word comes first if set to TRUE.
ACTIVE TIMEOUT
768
Process active timeout period.
DOC-0017-10-EN: AC20 Series PROFINET IO Option
Default Value
Range
1: None
0: Unknown
1: None
2: CANopen
3: EtherCAT
4: Ethernet IP
5: Modbus RTU
6: Profibus
7: Profinet
0: External
0: External
1: Fixed
2: DHCP
0
0
0
31: 31
0: IP Config Enable
1: Web Enable
2: Web Parameters Enable
3: FTP Enable
4: FTP Admin Mode
0
9: Auto
0: 10 kbps
1: 20 kbps
2: 50 kbps
3: 100 kbps
4: 125 kbps
5: 250 kbps
6: 500 kbps
7: 800 kbps
8: 1000 kbps
9: Auto
10: Lss
4: 19200 BPS
0: 1200 bps
1: 2400 bps
2: 4800 bps
3: 9600 bps
4: 19200 bps
5: 38400 bps
6: 57600 bps
7: 76800 bps
8: 115200 bps
0: Even 1 Stop
0: Even 1 Stop
1: Odd 1 Stop
2: None 2 Stop
3: None 1 Stop
FALSE
0
0 to 65
DOC-0017-10-EN-B 04.04.2023
Units
Type
Writable
ENUM
CONFIG
ENUM
CONFIG
ADDR
CONFIG
ADDR
CONFIG
ADDR
CONFIG
WORD
CONFIG
USINT
CONFIG
ENUM
CONFIG
ENUM
CONFIG
ENUM
CONFIG
BOOL
CONFIG
TIME
CONFIG
41 (47)