List Of Process Data; Programming With Siemens Plc - Parker 2003-PB-00 Technical Manual

Profinet io– communication option
Hide thumbs Also See for 2003-PB-00:
Table of Contents

Advertisement

DOC-0017-10-EN: AC20 Series PROFINET IO Option

9.2 List of process data

Read / Write Process Data mapping list for master/PLC
AC20 Input Mapping
1212 Input Demultiplexer 1
2061 Input B Value Func 1
0584 Digin Invert
0626 Digout Invert
0497 Remote reverse
0498 Rem Trip Reset
AC20 Output Mapping
0507 Status Word
0462 Reference
0103 Speed rpm
0534 Anin1 Value
0540 Anin2 Value
0558 Anout1 Value
0563 Anout2 Value
0610 Digin Word
0625 Digout Word

9.3 Programming with Siemens PLC

The example uses Siemens S7-1212C as controller PLC and Tia Portal V14 as programming Environment.
Prior knowledge of TIA Portal software is assumed.
Create a project
Launch the Tia portal software from desktop then click Start and select Create new project.
Define project properties and click on Create.
22 (47)
Data Type
Comments
WORD
Control Word
REAL
Speed Setpoint
WORD
Invert digital input
WORD
Invert digital Output
BOOL
Invert motor Rotation
BOOL
Trip Reset
Data Type
Comments
WORD
Status Word
REAL
Speed Reference
REAL
Speed Feedback
REAL
Analog In1 Value
REAL
Analog In2 Value
REAL
Analog Out1 Value
REAL
Analog Out2 Value
WORD
Digital Input state
WORD
Digital Output state
DOC-0017-10-EN-B 04.04.2023
PLC Module
Output
PLC Module
Input

Advertisement

Table of Contents
loading

Table of Contents