POWER SUPPLY

The device uses an auto-range power supply that accepts input voltages between 100 und 240 volts.
1
Connect the device via the mains cable to a grounded mains socket. Thus the unit is switched on.
2
To switch off the unit, disconnect the power plug.
3
Do not connect the unit to the mains voltage via a dimmer. For a more convenient operation, use a mains
outlet which is switchable.
4
The jack POWER OUT allows for power supply of further devices. To interconnect several devices,
connect the jack POWER OUT to the input POWER IN of the next unit until all units are connected.
Matching power cables are available as accessories. In this manner, up to 8 devices can be linked at
230/240 input voltage and up to 4 devices at 110/115 input voltage.

OPERATION

Connect the device via the mains cable to a grounded mains socket. Thus the device is switched on and
starts running.
The display lights up and you can choose the desired mode via the buttons MENU, ENTER, UP, DOWN.
The device has two operating modes. It can be operated in stand-alone mode via the control board and the
EUROLITE IR-38 remote control or in DMX-controlled mode via a standard DMX controller as well as
wireless
via
QuickDMX
Transmitter/Receiver.

Stand-alone mode

In the stand-alone mode, you can do without a controller. Disconnect the device from the controller and call
the desired setting. Please refer to the instructions under Control Board.

Interconnecting several devices (master/slave operation)

Several devices may be interconnected (max. 32). Then all slave units can be synchronized and controlled
with the master unit without the need for a DMX controller. The devices must be set to the corresponding
operating modes.
1
Configure all slave units before connecting the master unit: Press the MENU button so many times until
MASTSLAV is indicated on the display. Confirm with the ENTER button.
2
Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the
DMX output of the first slave unit to the DMX input of the second slave unit, etc. until all units have been
connected in a chain. Make sure the master unit is the first in the chain. Do not connect a DMX controller
to the DMX input of the master unit.
3
Set the master unit to the desired operating mode. The interconnected devices will now operate
synchronously.
with
the
optionally
24/32
available
EUROLITE
QuickDMX
USB
Wireless
00143606, Version 1.0