Visca Port: Set Visca port, the device will restart automatically after changed (default
3001,0-65535 optional).
Https Port: Set http port, the device will restart automatically after changed (default
443, 0-65535 optional).
WebSocket Port:Set WebSocket port, the device will restart automatically after
changed (default 8088, 0-65535 optional).
Click on the "Save" button, it will be valid when display "Save successful".
RTMP access: RTMP: / / equipment IP address: 1935 / live/av0 (av0 main stream;
av1 second stream)
RTMP Access:Rtmp://equipment IP address: 1935 / live/av0 (av0 main stream;
av1 second stream)
2)Ethernet Parameter
DHCP: Enable or disable obtain IP automatically can be set. After saved, reboot the
device to takes effect (default: OFF)
IP Address: Set the IP address, after saved, reboot the device to takes effect (default
192.168.5.163).
Note: This IP address is the same with the one used to login Web page.
Subnet Mask: Set the subnet mask (default 255.255.255.0).
Default Gateway: Set the default gateway (default 0.0.0.0).
Physical Address: Set the physical address (the parameter is read-only)
Click the "Save" button, it will be valid when display "Save successful". (Note: To
prevent IP conflicts when modify).
3) DNS parameters
Preferred DNS Server: Set the preferred DNS server. (Default 0.0.0.0).
Alternate DNS Server: Set alternate DNS server. (Default 0.0.0.0).
Click the "Save" button, it will be valid when display "Save successful".
4) GB28181
Switch: Set whether to activate GB28181.
Time Synchronization: Enable/Disable time synchronization
Stream Type: Set stream type (default main stream, secondary stream optional)
Signing Time (in seconds): 3600, range 5-65535
Heartbeat Time (seconds): 60, range 1-65535
Register ID: 34020000001320000001