PRODUCT IDENTIFICATION
MODEL #
MFG #
P1227801F
DEHUM1
P1221001
EFR01
P1221002F
HA02
P1129112F
MOD E L #
MFG #
LPLP0 3
N/A
N/A
LPM -0 6
SBT1 7
SBT2 1
N/A
10
Dehumidistat . Wall mou nted, 24 volt hu midity control available as a Dehumidistat used to
reduce the airflow in th e air conditioning mode to lower the humidity in an occupied home. This
control features a moisture-sen sitive nylon element and also provides positive On-Off settings
for manual operatio n. The control i s a normally cl osed switch that opens on humidity rise
causing the blower to switch to a lower spe ed to control the humidity within the structure.
External Filter Rack Kit . For u se with upflow gas fu rnace models. This kit is i ntended to provi de
a location, external to the furnace casing, for installation of a permanent filter. The rack is
mounted over the ind oor air blower compartment area of either side panel, and p rovide filter
retention as well as l ocation for attaching return air ductwork.
High Altitude Kit . The kit is desi gned to convert 80% gas furnace models at higher alti tudes.
This ki t is required when installing these furnace s above their maximum rated altitude. This kit
contains # 43-49, 55-58 gas orfices. The orfice s in the kit have been sele cted as a result of
testing with the American Gas Association. they will provide appropriate derating at the altitude
liste d in the High Altitude Charts as shown in the i nstallation instructions of the kit.
LP Ga s Low Pre s s ure Kit.Fo r u s e w ith fu rn a ce s co n ve rte d to L P g a s . Th is kit in clu d e s
h a rn e s s a d a p to rs to w o rk w ith Wh ite -R o d g e rs s in g le & tw o s ta g e g a s va lve s , H o n e yw e ll
s in g le a n d tw o -s ta g e g a s va lve s , a s w e ll a s m o d u la tin g g a s va lve s .
LP Conve rs ion Kit. Fo r u s e w ith 2 -s ta g e m o d e ls u s in g a Wh ite -R o d g e rs 3 6 G5 4 2 -s ta g e
g a s va lve kit o r a H o n e yw e ll VR 9 2 0 5 2 -s ta g e g a s va lve kit. In clu d e s re g u la to r s p rin g s ,
# 5 5 o rifice s , in s tru ctio n s a n d la b le to s h o w th e fu rn a ce h a s b e e n co n ve rte d to L .P.
Dow nflow Subba s e . Fo r u s e w ith 8 0 % d e d ica te d d o w n flo w fu rn a ce m o d e ls . Th e s e kits
a re a va ila b le fo r th e fo llo w in g fu rn a ce w id th s : 1 7 .5 " w id e (SBT1 7 ), 2 1 " w id e (SBT2 1 )