FITTING THE WOK BURNER

To fit the double crown wok burner:
Insert in the following order:
1. burner ring (A);
2. decorative covering ring (B);
3. external burner cap (C);
4. internal burner cap (D).
Note: make sure that:
1. the locating pin for the burner ring (A) is inserted correctly in
the slot on the burner unit.
2. that the locating pin on the
external burner cap (C) is
inserted in the slot on the
burner ring (A).
REGULATING THE MINIMUM FLOW LEVEL
OF THE GAS TAPS
Regulating the minimum flow level must be done with the tap at
the lowest position (small flame) .
There is no need to regulate the primary air in the burners.
To ensure the minimum level is properly regulated, remove the
control knob and adjust the screws found on the tap as follows:
1. tighten to reduce the height of the flame 1 (-)
2. slacken to increase the height of the flame (+);
3. With the burners on, rotate the buttons from the
maximum
to the minimum position
of the flame.
Once you have finished regulating, close up the seals again using
sealing wax.
to check the stability