Epson Stylus OFFICE B30 Service Manual page 41

Color inkjet printer
Table of Contents

Advertisement

EPSON Stylus C110/C120/D120/WorkForce 30/EPSON Stylus OFFICE B30/T30/T33/ME OFFICE 70
Occurrence timing
Detailed phenomenon
CR position
When turning on the power, the CR
Motor does not operate at all.
• Power on
• Anywhere
When turning on the power, the PF Motor
does not operate at all.
TROUBLESHOOTING
Table 3-3. Check point for fatal error according to each phenomenon
Defective unit/
part name
1. Check if the CR Motor Connector Cable is connected to
CN8 on the Main Board.
CR Motor
2. Check if the CR Motor Connector Cable is not damaged. 2. Replace the CR Motor with a new one.
3. Check if the CR Motor operates.
1. Check if the PF Motor Connector Cable is connected to
CN9 on the Main Board.
PF Motor
2. Check if the PF Motor Connector Cable is not damaged. 2. Replace the PF Motor with a new one.
3. Check if the PF Motor operates.
Troubleshooting
Check point
CN8
CR Motor
Connector Cable
CN9
PF Motor
Connector Cable
Revision C
Remedy
1. Connect the CR Motor Connector Cable to CN8
on the Main Board.
3. Replace the CR Motor with a new one.
1. Connect the PF Motor Connector Cable to CN9
on the Main Board.
3. Replace the PF Motor with a new one.