Dover ProGauge MagLink LX 4 Configuration Manual

Dover ProGauge MagLink LX 4 Configuration Manual

Hide thumbs Also See for ProGauge MagLink LX 4:

Advertisement

ProGauge MagLink LX 4 and LX Plus
Configuration Manual
Part Number: M2051
Revision: 4
MagLink LX 4 and LX Plus

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ProGauge MagLink LX 4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dover ProGauge MagLink LX 4

  • Page 1 ProGauge MagLink LX 4 and LX Plus Configuration Manual Part Number: M2051 Revision: 4 MagLink LX 4 and LX Plus...
  • Page 2 M2052 LX 4 and LX Plus User Manual M2054-QS LX 4 and LX Plus Quick Start FMM2058-PLS LX Plus Wiring Diagram FMM2058-PG LX Plus Wiring With ProGauge M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 3 Fax +39 0362 1581464 Copyright Information © 2020 Dover Fueling Solutions. All rights reserved. DOVER, the DOVER D Design, DOVER FUELING SOLUTIONS, and other trademarks referenced herein are trademarks of Delaware Capital Formation. Inc./Dover Corporation, Dover Fueling Solutions UK Ltd. and their affiliated entities.
  • Page 4: Table Of Contents

    6.1.8 Site Mapping (for Reconciliation/Autocalibration mode only) 6.1.8.1 Map Dispensers and Nozzles to Tanks 6.1.9 IFSF 6.2 Notifications Menu 6.2.1 Contacts 6.2.2 Notifications 6.3 Tank Setup Menu 6.3.1 Settings 6.3.2 Thresholds M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 5 Section 8 Tank Status Section 9 Sensor Status Section 10 Tank Group Status Section 11 Reports Menu 11.1 History 11.2 Tank Alarms 11.3 Sensor Alarms 11.4 Line Alarms M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 6 12.3 Network Configuration 12.4 Utility 12.5 Diagnostic (for LX Plus Only) 12.6 Console Settings Section 13 Change Password Section 14 Logout Section 15 Guest Account Section 16 Technical Support M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 7: Section 1 Preface

    Making copies, citing quotes or other reproductions of all or part of this document is permitted only after written consent of Start Italiana S.r.l. Patents protect trademark or name. Copyright 2022© Start Italiana S.r.l. – All rights reserved M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 8: Section 2 General Warnings

    This connection must have a cross-sectional area of at least 4 mm2 for the added earth connection. WARNING: Substitution of components can decrease intrinsic safety. ADVESTISEMENT: La substitution des composants peut compromettre la sécurité intrinsèque M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 9 READ CAREFULLY: The control drawing shown in ILL. 14 shall be provided with all devices. IMPORTANT: If a replacement power supply cable is necessary, use an applicable, approved ELBZ/7 type power cord. Do not use another type of power cable. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 10: Section 3 Introduction

    Data Description Name START ITALIANA S.r.l. Via Natta 6 Address 20823 Lentate Sul Seveso, (MB) Italy Telephone +39 0362 1581465 +39 0362 1581464 Website www.startitaliana.com e-Mail support@startitaliana.it M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 11 INFORMATION: The units of measurement contained in this manual refer to a specified selection by the user. Refer to "System" on page 22 for more information on how to set units of measure. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 12: Safety Warnings

    Indicates instructions and procedures related to safety or gives the location of safety equipment 3.2 Information Panels NOTE: This panel gives more information about an instruction or procedure. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 13 TIP: A step or procedure that is recommended to make another step or procedure easier. INFORMATION: This panel shows references to more information in other sources. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 14: Section 4 Direct Connection

    Navigate to C o n t r o l P a n e l > A l l C o n t r o l P a n e l I t e m s > N e t w o r k a n d S h a r i n g C e n t e r on your laptop. 1. Click Change adapter settings in the left-side panel. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 15 2. Right-click Local Area Connections. 3. Select Properties from the menu. 4. Select to highlight Internet Protocol version 4 (IPv4) on the list in the pop-up. 5. Click Properties. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 16 7. Click OK. Your laptop is now set up to communicate directly with your MagLink LX 4 console. Enter the IP address into your browser to connect. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 17: Section 5 Login Procedure

    A Guest User cannot make changes to the configuration. Admin: Has the same rights as Guest and can also make changes to the configuration. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 18 Association of alarm to relays (per tank) Managing internal and external sensors Automatic print features Managing strapping tables Configuring email address book Configuration of all dispensers TCP/IP address configuration, DNS M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 19 Touch screen calibration of the console; Restarting the console, Restarting the operating system of the console) Reconciliation (if enabled) Shift report with scheduling Sensors current status Autocalibration Analysis Tanks, sensors, Line leak setup M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 20: Section 6 Admin Account

    TIP: It is recommended to start from the Site Info tab and complete all applicable fields. Then, continue to the next tab to the right and complete all applicable fields. Continue this procedure until you have completed all tabs. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 21: System Settings

    This read-only field shows the number of pumps configured for reconciliation/autocalibration. Total dispensers Total sensors This field shows the number of environmental sensors configured in the console. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 22: System

    NOTE: All fields have selections (but not Alarm settings/Tolerance & Leak threshold) with default values. Changes to level and/or volume unit and number of decimals can automatically change with the selection. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 23 Short: The buzzer will operate for 30 seconds. It will stop automatically. Mute: The buzzer will not operate. The Dip-switch Settings field shows the function of the dip-switches. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 24: Protocols

    Click YES if the POS/FCC will transmit the dispenser sales transactions to the console. The Gilbarco Sales BCD protocol is supported for this function. Note, that only one connection at a time can support the sales transactions. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 25: Tank Group

    Tanks setup from the Main Menu. This tab is used to make Siphon (Manifold) groups. IMPORTANT: Tanks in a Siphon (Manifold) group must contain the same product. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 26: Shifts

    The "Shifts" screen is used to configure shift reports. A shift report shows the tank contents at the beginning and end of the shift. The shift report is made in another menu. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 27: Fairbanks

    (sudden loss) event. This is applicable to tanks in Standard mode only. 6.1.6 Fairbanks The console can send information to a Fairbanks server through FTP if applicable. This information includes: Inventory stock levels Deliveries Alarms M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 28: Smtp

    SMTP port, provided by the mail Server Enable SSL Activate it for SSL connections. Use the TEST button to send a test email to a specified recipient. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 29: Site Mapping (For Reconciliation/Autocalibration Mode Only)

    Max nozzles Identifies the maximum number of nozzles for each pump. Click Save when you complete the top section of the Site mapping tab configuration. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 30: Map Dispensers And Nozzles To Tanks

    Click the Save Mapping button at the bottom of the panel to save the configuration. 6.1.9 IFSF This is not in use at this time. Ignore this section. For IFSF connections, the external IFSF module must be used. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 31: Notifications Menu

    Click NEW CONTACT to configure notification information for a new contact name. The New Contact window will come into view. Complete the fields: Name Email: To receive notifications by email M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 32: Notifications

    An alarm related to a PLLD test that failed. Line A report with PLLD test history that can be started to be emailed from the GUI. Select the email recipients Compliance here. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 33: Tank Setup Menu

    A probe query does not occur if this button is OFF. b. Description: Enter a description of the tank. c. Select the product type from the Product family drop-down. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 34 OPW 924B: OPW 924B with 5 temperature sensors. OPW 924A: Previous generation OPW 924A probe with 5 temperature sensors. VSmart analog: For OPW 7100V flexible probes that connect through the Vsmart module. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 35 Offset water: This value is used to calibrate the water float Possible value range: ±5000 mm (197 in). l. Water Min Float Level: This is the threshold to set the water volume at zero and show the water level. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 36: Thresholds

    1. Select Thresholds from the configurations parameters. Use one of two methods to adjust each of the parameter values: a. Move the slider until you get the correct values. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 37 %) must be lower than the one above it. For example, the Low Threshold must have lower values than the High Threshold. If the values are not set correctly, the SAVE button will not be M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 38: Density

    Use either of the two values to calibrate the density sensor (the system will automatically change the B value to adapt to the manually entered hydrometer density. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 39: Aef (Aqueous Ethanol Float) Thresholds

    Four (4) thresholds will show that will must be calculated. The current AEF reading value is used by the console to automatically make these calculations. T2: AEF position in normal product t2: AEF position when lift begins in ethanol (phase separation has started) M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 40: For Opw 924B Probes With Aef

    6.3.4.2 For OPW 924B Probes with AEF The OPW-FMS AEF on a 924B probe measures the density at the bottom of the tank. The setup screen is shown in the image below: M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 41 Ethanol alarm threshod and t1 Water alarm threshold. The system recommends default values for these thresholds however, the user can overwrite them. 3. Click Save when you complete the configuration. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 42: Relays

    The available alarms/actions that can be linked to a relay: Disabled High/High Water No Link Low/Low Ethanol High Probe Error Leak No Leak Test Sudden Loss High/High Water Click Save when you complete the Relays configuration. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 43: Straptable

    A selected strapping table can be exported to a csv format that can be saved in a spreadsheet or text editor. Click the CSV Export button to continue. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 44 Select the Generate button. The bottom of the screen shows the volume to height graph and the volume distribution (liters per unit of height). See the screenshots below: M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 45: Leak Test

    External factors can affect the test results (such as ground vibration, extreme winds that cause too much evaporation, probe failure or a sticky float, incorrect tank charts). M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 46: Leak Test Setup

    OPW 924B probes the threshold can be 0.2 gph or 0.1 gph. 8. Push Save to save this configuration For a Scheduled Test, select a date from the date picker, then configure the parameters as above. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 47: On-Demand Test

    6.3.7.2 On-demand Test From the tank status tab, click on the Leakage test drop-down menu. Use the Start/Stop buttons to start or to stop a test. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 48: Acr Mode

    Autocalibration. This would also increase the time to complete Autocalibration. Low segment: This shows the lowest segment of the calibration range. High segment: This shows the top segment of the calibration range. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 49: Acr Results

    3. The Soft reset button will delete the number of calibrations but will keep the autocalibration table. This lets the user improve the autocalibration if the autocalibrated data is not sufficient. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 50: Reconciliation

    Loss alarm (liters): A difference more than this threshold will cause a Loss Alarm. Unaccounted variance (%): If a difference in the daily reconciliation is more than this threshold, it will cause an alarm. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 51: Section 7 Sensor Setup

    Select where the sensor is to be connected. Internal refers to the internal CN10 connector (only EXd sensors can connect to the CN10). For Intrinsically Safe sensors, select the MagLink I/O. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 52: Opw Fms Smart Sensors (Model Lx Plus Only)

    5. The Serial Number will automatically show when the sensor is detected. 6. Select a Location from the drop-down. This is used for information only. Click Save to save the Settings configuration. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 53: Relays

    No link Open 30-0234- Hydrocarbon liquid sensor with water Short indicator (6, 15, 24 ft lengths) 06/15/20 Water (when sensor detects water) High liquid (when sensor detects hydrocarbons) M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 54 Warning/Alarm message generated on console number 10-SL1-L110-C No link On/Off sensor 10-SL1-L110- High 10-SL2-L200- No link Discriminating sensor High (when top float lifts) 10-SL2-L200- Water (when bottom float lifts) GJKE M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 55 Warning/Alarm message generated on console number No link 3-XRF600GAB- Wireless (2 floats) High (when top float lifts) D1R0-DSC Water (when bottom float lifts) No link 3-XRF600GAB- Wireless (1 float) D1R0-DSC High M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 56: Section 8 Tank Status

    The graph on the right side of the screen will scroll automatically to show the information that follows: Product / water height Product volume / Product volume TC Water volume Density / TC density Temperature M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 57 The bottom of the screen shows information on the Deliveries, Leak Tests and Autocalibration. Delivery: Click on the Delivery drop-down menu to show information on the last delivery recorded. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 58 Tank inventory is shown at the bottom of the page. TC volume refers to the temperature compensated volume. This is calculated through the API tables. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 59 M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 60: Section 9 Sensor Status

    3. The full sensor status is shown at the top of the panel. 4. Push the ACK IS REQUIRED button to acknowledge the alarm. This will also stop the alarm buzzer. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 61: Section 10 Tank Group Status

    Section 10 Tank Group Status A summary of the tank group is shown on this screen: Gross volume (at 15°C) Water volume Mass (in Kg) M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 62: Section 11 Reports Menu

    Tank Alarms Sensor Alarms Line Alarms (LX Plus models only) Product Deliveries Tank Leak Tests Line Leak Tests (LX Plus models only) Compliance Pump Sales Shifts Reconciliation M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 63: History

    1. Select a Tank Number from the drop-down. Alternatively, use the slider button to select All tanks. 2. Use the date selector to select a From Date and To Date for your report. 3. Click the Load button to show the data. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 64: Sensor Alarms

    1. Select a Line from the drop-down. Alternatively, use the slider button to select All Lines. 2. Use the date-selector to select a From Date and To Date for your report. 3. Click the Load button to show the data. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 65: Delivery

    4. The Delivery Report can be exported to a csv format that can be saved in a spreadsheet or text editor. Click the CSV Export button to continue. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 66: Tank Leak Tests

    The start and end time of the test The Leak threshold The volume difference between the start-end (at ambient temperature and temperature compensated) The result of the test and if the test was aborted. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 67: Line Leak Tests

    The Running pressure (the running pressure is the pressure in the pipeline which is recorded once the STP has stopped to pressurize). The LLD leak test result. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 68: Compliance

    11.8.2 Line Compliance Report This report shows a summary of LLD tests done for each line line "today" and in the last 24 hours and identifies the last test passed. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 69: Sales

    1. Select a Tank Number from the drop-down or use the slider button to select All tanks. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 70: Shifts

    1. Select a Tank Number from the drop-down. 2. Use the date selector to select a From Date and To Date for your report. 3. Select a report type (Hourly, Daily, Petroleum). M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 71 ACR settings in the Tank Setup). The difference because of the water change in liters between the current hour and the hour before. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 72 ATG measured delivery and invoiced delivery (invoice detail entered manually during delivery report). The result is shown in liters and as a % of tank sales. Tank depletion: The quantity of liters physically kept in the tank. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 73: Configuration

    PC. Use the three (3) relay slider buttons (“Print Tanks Relays,”Print Sensors Relays,” “Print LLDs Relays") to include relay configurations for the different modules. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 74: Section 12 Maintenance

    IMPORTANT: There are separate manuals for Installation. M2050 is for the installation of the LX 4 console and M2050-PLUS is for installation of the LX Plus console. 12.2 Timezone M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 75: Network Configuration

    3. Click Save. The console application will restart. 12.3 Network Configuration 1. Enter the network parameters into the applicable fields 2. Click Save when you have completed all applicable fields. 12.4 Utility M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 76 Click the Reboot button to restart the console. Click the Cold Reset button to put the console back in original factory default settings. This procedure will remove the database. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 77: Diagnostic (For Lx Plus Only)

    12.6 Console Settings In this section, the numeric password to get access to the Maintenance section on the Graphical User Interface of the console can be changed. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 78 The timeout session gives the time that the user can be logged in to the Maintenance section before the system automatically logs the user out. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 79: Section 13 Change Password

    TIP: As you type your password only neutral "bullet" characters will show (e.g. • • • • • •). Select the "eye" icon to show the password characters as you type. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 80: Section 14 Logout

    Section 14 Logout Select Logout from the Main Menu. The Login screen will come into view. Click the Logout button to log out of the console. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 81: Section 15 Guest Account

    Section 15 Guest Account A Guest account only gives access to the Tank Status page and a view of data from Reports. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 82: Section 16 Technical Support

    Refer to "Utility" on page 75 for information on log files and the database backup in the console. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 83 4. Name: Enter a name to identify the line. 5. Tank: Select the tank number from the drop-down that has the STP with the PLLD sensor installed. MAGLINK I/O (PLLD-DAS in new software versions) M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 84 8. Position: Enter the Position (connector slot) where the PLLD sensor is connected to the PLLD board. The PLLD board has 8 connector slots. NOTE: For PLLD-DAS: Position 1 is at the top (CH1). See the illustration below. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 85 NOTE: For MagLink I/O: Slot No1 is next to the Green LED. Slot No8 is on the opposite side of the Green LED. See schematic below. The PLLD board must be installed on the top slot of the I/O, see the image below. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 86 NOTE: If your pipeline is not listed here, you can select the closest pipeline and manually enter the volume/length parameter in the next field (it will override the automatically selected volume/length). M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 87 This will cause the system to start the calibration once the nozzle is back into the cradle. This method is used to start the calibration M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 88 Automatic LLD leak test – click the Save button to save the settings 1. Enabled: When this button is “Enabled,” the system will run a leak test automatically that uses specified frequencies. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 89 STP CONTROLLER (the STP contactor fused or stuck) LINE LEAK (a leak test failed) NO LEAK TEST (no leak test has been done as the WARNINGS setup in the Leak Test tab) M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 90 In the example shown in the image above, an HH Water alarm event on Tank 1 has been caused that will shutdown the STP after 10 continuous hours that the alarm is active. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 91 12. Reference Pressure: This is the reference pressure at which the test will run. A 3 gph test is referenced at 10 psi. 13. Running Pressure: This is the pressure in the pipeline once the STP has stopped fueling. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 92 5400 0,008 0,0119 0,0012 DUALOY 3000/FLS III 7600 0,014 0,0209 0,0021 BRUGG FLEXIBLE PIPE TYPES BETA Gals/inch Liters/cm Liters/mm FLEXWELL HL-40 (1.5 INCH) 33000 0,008 0,0119 0,0012 M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 93 8600 0,008 0,0119 0,0012 SMARTFLEX (2.0 INCH) 15000 0,014 0,0209 0,0021 PETROTECHNIK FLEXIBLE PIPE TYPES BETA Gals/inch Liters/cm Liters/mm UPP EXTRA (63 mm) 1500 0,014 0,0209 0,0021 M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 94 14500 0,008 0,0119 0,0012 C20 (2.0 INCH) 11000 0,014 0,0209 0,0021 C30 (3.0 INCH) 4100 0,031 0,0462 0,0046 WIRING DIAGRAM Refer to FMM2058-PLS LX Plus Wiring Diagram. M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 95 M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 96 On W e b U I > T a n k s s e t u p > S e t t i n g s S e r i a l N u m b e r , the Radar device address must be entered. After "QUERY PROBE" the system should automatically adjust the probe type to "Radar LR120." (Continued on next page) M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 97 When a liquid is selected in the "Product Family" drop-down, the "Application type" list-box will show the values below (see the screen image below): Storage Process Wetwell Plastic Open (Continued on next page) M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 98 When "Solid" is selected in the "Product family" drop-down, the "Application type" list-box will will show the values below (see the screen image below): Silo Bin/Hopper Open M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 99 AEF w/PG and 9/11/2023 OPW, PLLD, PLLD-DAS, Siemens LR120 Radar setup. NOTE: It is possible that older software versions might not support all features M2051_r4 MagLink LX 4 and LX Plus Configuration Manual | Dover Fueling Solutions...
  • Page 100 ©2023 Dover Fueling Solutions. All rights reserved. DOVER, DOVER D Design, DOVER FUELING SOLUTIONS and other trademarks mentioned herein are trademarks of Delaware Capital Formation Inc., DoverCorporation, Dover Fueling Solutions UK.

This manual is also suitable for:

Progauge maglink lx plus

Table of Contents

Save PDF