I I m m p p o o r r t t a a n n t t : : When installing a 21.0" wide S-Series
furnace, the condenser trap grommet must
be rotated so that the notch in the grommet
faces the outer edge of the furnace cabinet
as shown in the illustrations below and to
the top left in next page. This allows the
rain gutter tubing to fully seat onto the
lower condensate port trap.
30. Hand tighten screw.
S9V2-SVX001-1B-EN
F F u u r r n n a a c c e e C C o o m m b b u u s s t t i i o o n n A A i i r r E E x x h h a a u u s s t t O O p p t t i i o o n n s s
31. Connect PS2 tubing to switch and new sensing
location. Use additional tubing in ship with bag, if
necessary.
I I m m p p o o r r t t a a n n t t : : Trim the condensate pressure switch
tubing to length to ensure there is no sag or
trap created.
32. Remove port cap on the right side of inducer and
connect inducer condensate tubing. Connect other
end of inducer condensate tubing to top port on the
condensate trap. Cut tubing to length, if necessary.
33. Install previously removed port cap onto bottom
port of the inducer. (As viewed in upflow)
34. Connect condensate pressure switch tubing to
pressure port on the condensate trap.
I I m m p p o o r r t t a a n n t t : : Cut to length to ensure there is no sag
or trap created.
35. Remove port plug from rain gutter and install in
new position on opposite side of the rain gutter.
36. Connect rain gutter condensate hose to the rain
gutter and the lower port of the condensate trap.
Route rain gutter condensate hose to the right of
the inducer motor.
31
32
35
36
33
34
89