Page 1
USER MANUAL Pharmacy Refrigerator [MODEL] KBU5L316 KBU5L416 KBU5L756 KBU5L1006 Warning: Before using this product,please read this manual carefully and keep it for future reference.The design and specifications are subject to change without prior notice for product improvement. Consult with your dealer or...
Product features This product can be used to store medicines, vaccines, reagents and materials ~ °C. that need to be stored at 2 8 Product function Accurate temperature control & traceable data • Microcomputer temperature control displays accuracy of 0.1°C •...
Precautions and safety measures Dear users of Kings bottle: Hi! Thank you for using Kings bottle harmacy refrigerator. For your c onvenience to understand this manual, use the product,and prevent personal injuries and goods damages, please read the following instructions thoroughly. Failure in complying matters Actions or Warning...
Page 7
If the power cord needs to be lengthened, the sectional area of the lengthened cord shall not be less than 2.5mm . At the same time, the length is not longer than 3 m. Otherwise, it may cause a fire or electric shock. In case of flammable gas leakage, it is necessary to close the gas leakage valve and open doors/windows, for ventilation.
Page 8
If the pharmacy refrigerator is not working properly, please unplug the power plug. It may cause electric shock or fires if it continues to operate under abnormal conditions. Before any repair or maintenance of the pharmacy refrigerator, always disconnect the power supply of the pharmacy r fri rator to r r ona in ri...
Page 9
Do not climb on the pharmacy refrigerator or put the stuff on the pharmacy refrigerator, otherwise will fall over and r ona in ri or ama to t arma y r fri rator. Don't use the pharmacy refrigerator in the open air. When the pharmacy refrigerator is wet by rain, it may cause electric leakage or electric shock.
Page 10
--------------------------------------------------------------------- Note There should be no obstruction around the pharmacy refrigerator and the ventilation should be smooth. It is necessary to check the pharmacy refrigerator setting when restarting the pharmacy refrigerator after power failure or power off. Changes in settings may damage stored items. Once the power of the pharmacy refrigerator is cut off, it will take more than five minutes to turn it on again to avoid damages to the compressor or system.
Precautions for use in the storage room has reached the set temperature, and then put the stuff The volume of the articles in the into the pharmacy refrigerator in batches. box should not exceed 1/4 of its volume at a time to prevent the temperature from rising too much.
Product installation Product handling --------------------------------------------------- Protect the pharmacy refrigerator in moving it, same as shown as below photo, please move it by handcart with cushion. Remove all packing materials and bottom cushion, then move into house for placement. After moving it to appropriate location, wait for 2 hours before power on. Installation environment ------------------------------------------ pharmacy refrigerator is only for indoor use, with second pollution level and...
Page 13
Installation site ------------------------------------------------------ Do not install the device in a narrow and confined space and install it in a place that can ensure its normal access, to avoid damage to storage goods by maintenance difficulties and delayed repair in case of device failure. The installation floor must be solid, flat, non-combustible and able to bear the weight of the device during operation.
Page 14
Preparation before use ------------------------------------------- 1. Remove the outer packaging of all products (including the protective foam in the packing box). 2. Check the accessories; please check the contents in the box according to the packing list. If there is any discrepancy, please contact the after-sales service in time.
Page 15
Initial start-up ------------------------------------------------------ Please observe the following rules when conducting initial start-up: 1.Under no-load condition, please connect the power plug to right plugboard, and the plugboard should not be shared with other appliances. 2.After turning on the power supply, turn on the battery switch of the device, check if the inner LED light works properly.
Page 16
• A special person shall be responsible for the operation of this product, and check and record it every day. If the temperature in the cabinet is too high or too low, the goods shall be transferred to other pharmacy refrigerator, and the goods shall not be stored again until the fault is eliminated.
USB panel Glass door lock LED light Refrigeration air duct Refrigeration fan Steel wire shelf Glass door Universal wheel Schematic diagram (eg:KBU5L316 , KBU5L416) Door light switch Control panel USB panel Glass door lock LED light Refrigeration air duct Refrigeration fan...
Operating instructions Operation and display panel Temperature Humidity ALARM DOOR SET /MUTE PRINT LIGHT Digital tube display instructions The right digital tube only displays humidity and keeps humidity display unchanged, while the left digital tube displays temperature, alarm codes, menu, parameters and other information. The “digital tube”...
Key functions Key names Key symbols Key names Set/Mute key Up key Down key Print key Light switch Key operation Key lock function a) When the key is unlocked, the key will be locked if there is no key operation for 60s or Up key and Down key are pressed for 3s at the same time.
Page 21
Key unlocked password setting example(set password from 5 to 7) Steps Operation Display shows Press key to unlock(refer to previous instruction) Press Set/Mute key 3s Press Up key, Down key to choose settable parameter”PS1” Press Set/Mute key Press Up key, Down key to change parameter to 7 Press Set/Mute key 3s to save parameter and quit Start the recorder When the key is unlocked, when the recorder is not started, the digital tube...
Page 22
”Month”setting example(other r,s,F,Pt,SCY setting refers to this example) Please finish setting in 2 minutes. If no operation, it will automatically quit in 2 minutes and shows normal. Please export previous data record before changing recorder time and data recording interval time, otherwise the data may be lost. Manually generate PDF files When the key is unlocked and no file is being generated, connect the USB flash disk and press the Up key for 3s until the digital tube displays “d01”.
Page 23
Record the temperature The recorder stores the data every 10min. Export the USB data (1) After the USB flash disk is connected to the USB interface, the recorder buzzer beeps once, the digital tube displays the upload data code “on” (in case of large amount of data) and the USB flash disk generates the PDF files on data of current month and last month.
Page 24
Printer (optional) Outer appearance Open Button Self Button,Error 3. Lf Button, Power indicator Paper roll Outer dimension 103 +0.2 +0.1 r ont size Paper install Press the button to open the door. After loading the paper roll, close the door.
Page 25
Light and button operation Online status switching button. Under online status, the interface printing is valid. Under offline status,【LF】button is valid. The default is online status when printer is power on. When printer is power on, this button is online status. At this time, pressing 【SEL】button to be offline status and press LF button to feed paper.
Page 26
self-test receipt In the figure, the left one is self-test receipt for serial interface model and the right one is for parallel interface model. The printing sequence is from the below to above. Mark: 1、Due to that the default configuration item may be different when the printer is out of factory, the font size of self-test receipt and the content of each configuration is according to the actual content of printed receipt.
Alarms Serial Alarm Alarms Alarm reason number code Alarm for high temperature in the Interior temperature cabinet >SEt+H Alarm for low temperature in the Interior temperature cabinet <SEt-L Ambient temperature High ambient temperature alarm >tH1 Door ajar time over Door open alarm 1 minute Low voltage alarm Low battery voltage...
Page 28
User menu parameter list Menu Menu Menu description Setting range Default Unit level Maximum temperature in the °C current time period (optional) Minimum temperature in the °C current time period (optional) Clear the record of the 0: clear maximum and minimum 1: not clear temperature in the current (optional)
Page 29
Glass door electrical heating mode instruction: Select 1 for glass door electrical heating mode P1: heating for 3 minutes after door opened and closed. If door opened and closed again during heating procedure, heating time will restart. Select 2 for glass door electrical heating mode P1: electrical heating turns on while compressor operating;...
Maintenance and care Warning To r r ona in ri make sure that power is disconnected before having any repairs or maintenance on the device. When maintaining the device, make sure that you do not inhale surrounding medications or suspended particles that could damage your health. Note Do not directly sprinkle water on the box, so as to avoid the decline of insulation performance of electrical components and rust of metal parts.
Page 31
End-of-life period: When the device reaches the end of its service life, it should be scrapped and must be handed over to qualified professional recycling organizations for scrapping and disposal in accordance with local regulations and ordinances; non-professionals should not disassemble or decompose the device without authorization;...
Troubleshooting and maintenance services When there is a failure in the product, please check and handle it according to the following table. If the situation cannot be changed, please inform Aegis Biological Service Center in time. We will serve you wholeheartedly to avoid any loss to you.
Packing list KBU5L316 KBU5L416 KBU5L756 KBU5L1006 *The warranty card and certificate are included in the instruction and the specific packing list shall prevail in accordance with the real product.
All cost for labor and materials is covered for 2-year from the date of receipt. If KingsBottle deems the unit not repairable, KingsBottle will use the value of your original order toward a replacement (Any replacement unit will follow the warranty terms of the initial purchase).