Download Print this page

Dialight Vigilant Operation & Installation Instructions

Area light with battery backup

Advertisement

Quick Links

These instructions contain safety information, read and follow them carefully. Dialight will not accept any
responsibility for injury, damage or loss, which may occur due to incorrect installation, operation or maintenance.
Operation/Installation Instructions
Page
1
Area Light with Battery Backup UL1598/A / UL844 / UL924
Important Information
Note:
Save these instructions for future use
use.
Note:
These instructions are for Battery Backup specific case only. For
general Area Light information, see supplemental instruction sheet
Dialight, 1501 Route 34 South, Farmingdale, NJ, USA 07727
Tel: 732 919 3119
Fax: 732 751 5778
9100HZC280501 REV B
www.dialight.com

Advertisement

loading

Summary of Contents for Dialight Vigilant

  • Page 1 Area Light with Battery Backup UL1598/A / UL844 / UL924 Important Information These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss, which may occur due to incorrect installation, operation or maintenance.
  • Page 2: Replacing The Battery Pack

    Replacing the Battery Pack 1. Open battery cover by unscrewing six 10-32 captive screws as shown to access battery pack connection. 9100HZC280501 REV B Dialight, 1501 Route 34 South, Farmingdale, NJ, USA 07727 Tel: 732 919 3119 Fax: 732 751 5778 www.dialight.com...
  • Page 3 3. Unscrew two 10-32 screws and slide battery pack out of housing. Discard old battery pack according to respective national regulations on waste disposal. 9100HZC280501 REV B Dialight, 1501 Route 34 South, Farmingdale, NJ, USA 07727 Tel: 732 919 3119 Fax: 732 751 5778 www.dialight.com...
  • Page 4 Torque to 28-30 in-lbs Figure A Figure B 5. Connect battery pack to battery driver as shown. 9100HZC280501 REV B Dialight, 1501 Route 34 South, Farmingdale, NJ, USA 07727 Tel: 732 919 3119 Fax: 732 751 5778 www.dialight.com Page...
  • Page 5: Battery Backup Function

    All other mounting options <12% @277VAC Size varies by mount type Temperature -4°F to +131°F [-20°C to +55°C] 9100HZC280501 REV B Dialight, 1501 Route 34 South, Farmingdale, NJ, USA 07727 Tel: 732 919 3119 Fax: 732 751 5778 www.dialight.com Page...
  • Page 6: Technical Diagrams

    All statements, technical information, and recommendations contained herein are based on information and tests that Dialight believes to be reliable. The accuracy or completeness thereof is not guaranteed. In accordance with Dialight “Terms and Conditions of Sale” and since conditions of use are outside our control, the purchaser should determine the suitability of the product for his or her intended use and assumes all risk and liability whatsoever in connection therewith.

This manual is also suitable for:

SafesiteAlu5bc27dgnngnAlu5bc27nnwngnAlu5bc29nnwngn