Replacing the Filters

Pump Filter
1. Loosen and remove the filter housing by hand.
2. Slip the filter off of the filter support spring.
3. Inspect the filter. Based on inspection, clean or replace the
filter.
4. Inspect the seal. Based on inspection, clean or replace the
seal.
5. Slide the new or cleaned filter over the filter support spring
with the adapter in place over the pin on the spring. Push the
filter into the center of the pump block.
6. Slide the filter housing over the filter and thread it into the
pump block until secure.
NOTE: The filter housing should be hand-tightened, but
make sure the filter housing is seated fully into the
pump block.
Filter support
spring
Seal
Pump
block
Gun Filter
1. Unclip the top of the trigger guard from the gun body.
2. Using the bottom of the trigger guard as a wrench, loosen and
remove the handle assembly from the gun head.
3. Pull the old filter out of the gun body. Clean or replace.
4. Slide the new filter, tapered end first, into the gun head.
5. Thread the handle assembly into the gun head. Tighten with
the trigger wrench.
6. Snap the trigger guard back onto the gun body.
NOTE: For more detail, part number information, and
complete assembly drawings, please see the RX-80
Airless Gun Owner's Manual.
English
Filter
Adapter
Filter
spring
Filter housing
Gun
Body
Filter
Handle
8