Ice-O-Matic CIM 300 Installation Manual And Owner's Manual page 6

Cim 300 lb through 2000 lb cubers
Table of Contents

Advertisement

ELEVATION SERIES
Route the refrigerant lines through the roof
opening. Follow straight line routing whenever
possible. Any excess tubing MUST remain with
the building. Spiral the excess length of pre-
charged tubing inside the building. Use a
horizontal spiral to avoid any traps in the lines.
Have the roofing contractor seal the holes in the
roof per local codes.
The following remote ice makers incorporate the Mixing Valve in the condenser. This configuration allows
up to a 100 foot calculated remote line set run. Reference the diagram on the next page to calculate the
maximum 100 ft. line set run. Maximum actual line set run is limited to 100 ft. Add 1/4 oz. of refrigerant
for each actual foot from 75 to 100 ft. actual line set run.
CIM Machine Model Number
CIM0530R
CIM0535R
CIM0636R
CIM0825R/0826R/0835R/0836R/0837R
CIM1125R/1126R/1135R/1136R/1137R
CIM1446R/1447R
CIM1545R/1845R
CIM2046R/2047R
*Verify the CIM machine is compatible with the remote condenser.
For more information contact your Ice-O-Matic distributor
REMOTE CONDENSER GUIDELINES
CAUTION: The couplings on the sets of pre-charged
lines are self sealing when installed properly.
Carefully follow the instructions in the Remote
Condenser manual
Remote Condenser Model Number
VRC1001B/RCA1001
VRC1061B/RCA1061
VRC1061B/RCA1061
VRC2061B/RCA2061
VRC2061B/RCA2061
VRC2661/RCA3061
VRC2661/RCA3061
VRC5061B/RCA3561
5