High current switching mode power supply with remote sensing & control

Advertisement

4.4.2 ENABLE AND DISABLE THE OUTPUT
You can use Port 7 and 8 to remote control the OUTPUT ON/OFF.
a) Open Port 7 and 8 if you want to ENABLE the output ( By default )
b) Short Port 7 and 8 if you want to DISABLE the output.
4.5 If you do not use the remote control feature, make sure the remote control ON/OFF switch is in OFF
position(Rear panel).
4.6 Switch on the power supply and the power ON/OFF LED should light up in green.
Then, adjust the output voltage to the desired voltage and switch off the power supply.
4.7 Connect the equipment to the power supply. Red (+) is connected to the positive polarity input of the
equipment and Black (-) is connected to the negative polarity input of the equipment.
4.8 Switch on the power supply first and the LED Indicator should light up in green.
4.9 Switch on the equipment and the LED Indicator should still remain in green.
4.10 You can now operate the equipment.
When an operation is finished, switch off the equipment first and then switch off the power supply.
4.11 When disconnecting the power supply from the unit, disconnect the remote sensing wire first, then
disconnect the output cables.
5. SPECIFICATIONS
Variable Output Voltage
Total Rated Output Current
(Main + Auxiliary Output)
Rated Output Current (Main)
Rated Output Current (Auxiliary)
Ripple and Noise
Load Regulation
Line Regulation
Input Voltage
Efficiency
Dynamic Power Factor Correction
Voltmeter and Ammeter Display
Meter Accurancy
Indicator
Special Feature
Cooling Method
Operating Temperature
Protections
Approvals
Dimension
Weight
SPS-9600
1 ~ 15V
60A
60A
5A
40mVp-p
0.1% + 5mV
0.05% + 3mV
230VAC / 50Hz ( or on request )
>85%
>0.97 at optimal load
3 digit LED display
+/- 1% + 1 count
Green LED for power on/off indication
Red LED for overload/short circuit indication
Remote Control & Remote Sensing
Variable Speed thermal static control fan
0 ~ 40°C
Overload(Constant Current Limiting), Short Circuit,
Overtemperature and OVP
CE-EMC: EN 55022 CE-LVD:EN 60950
220 (W) x (H)110 x 360(D) mm
5.8Kg
SPS-9602
1 ~ 30V
30A
30A
3A
7673-9602-0002