Manson Engineering Industrial HCS-3404 User Manual

Manson Engineering Industrial HCS-3404 User Manual

Laboratory grade & high rfi immunity switching mode power supply with rotary encoder control
Hide thumbs Also See for HCS-3404:

Advertisement

Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control
1. INTRODUCTION
Since the introduction of HCS series power supplies in 2009, we have made numerous improvement within the limits of
the original hardware modules, firmware and software framework.
In the upgraded version of HCS series power supplies, both the hardware and the firmware have been modified, the
application software has a completely design in concert with the value added features.
Added Features which can be done on the unit panel.
1. Reset no load current to zero on current meter.
2. Reset the 3 presets to factory default
2. WARNING
Do not use this power supply near water.
Do not operate or touch this power supply with wet hands.
Do not open the casing of the power supply when it is connected to ac mains.
Refer all servicing to qualified service personnel only.
Before replacing the AC fuse at AC socket , find out and clear up the cause first.
Replace the AC fuse with the same type and rating as the original fuse.
The max. output voltage of Model HCS-3404 is over 60VDC, avoid touch the metal contact part of the output
terminals.
Analogue Remote Control or Remote Programming via USB function is only suitable for stand-alone one unit
operation.
Do not use this power supply with electrical motors, solenoid or inductive load that generates a back EMF and
voltage transient which may damage the power supply
3. CAUTION
Use a grounded 3 pin AC source.
This unit is for indoor use only.
Do not operate or place this unit in a humid, dusty, in direct sunlight location or near any heat source.
Before plugging into local AC mains, check with the rating label at the back of the unit.
Do not block any ventilation openings of the unit.
This unit must be used within the specified rating, regular excessive continuous loading may cause damage to the
power supply.
The gauge size of input power cable must be at least 0.75mm
3m.
4. OPERATION ENVIRONMENTAL CONDITION
10-80% R.H.
Altitude up to 2000m
Installation category: CAT 2
Pollution degree: 2
Mains supply voltage fluctuation up to ±10% of the normal voltage
HCS-3400/3402/3404
User Manual
2
and the total length of power cable must not exceed

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HCS-3404 and is the answer not in the manual?

Questions and answers

Summary of Contents for Manson Engineering Industrial HCS-3404

  • Page 1 • Replace the AC fuse with the same type and rating as the original fuse. • The max. output voltage of Model HCS-3404 is over 60VDC, avoid touch the metal contact part of the output terminals. • Analogue Remote Control or Remote Programming via USB function is only suitable for stand-alone one unit operation.
  • Page 2: Controls And Indicators

    HCS-3402: The total rated current (Aux.+Main) is 20A HCS-3404: The total rated current (Aux.+Main) is 10A (7) Output Terminal (Rated 40A for HCS-3400/ Rated 20A for HCS-3402/ Rated 10A for HCS-3404) (8) Mode Selection Switch (Normal, Preset, Remote Control, Set Modes)
  • Page 3: Control Mode Selection

    Maximum HCS-3400: 15V Maximum HCS-3402: 25V HCS-3404: 55V 6.3 Set Mode – First enter into the Set Mode by pushing Switch (8) to Set Mode slot. The power supply is then ready to be preset. 6.3.1 To define the preset output P1/ P2/ P3.
  • Page 4: Using The Power Supply

    0 ~ 40A HCS-3402 1 ~ 32V 0 ~ 20A HCS-3404 1 ~ 60V 0 ~ 10A 7.2 Check the rating label of the power supply and make sure it complies with your AC mains voltage. Connect the power supply to the AC Mains using the provided power cord.
  • Page 5: Manually Zeroing Current Meter Offset

    7.5 Connect the equipment to the power supply. Red (+) is connected to the positive polarity input of the equipment and Black (-) is connected to the negative polarity input of the equipment. 7.6 Switch on the power supply first and the panel meter & green CV Indicator should light up again. 7.7 Switch on the equipment and the panel meter &...
  • Page 6 7.10 Reset 3 preset output P1/ P2/ P3 to factory default value In session 6.3, you learning how to set 3 preset output to you preferred value. In case you need to reset it to factory default, you can do it in MENU mode. Press and hold Voltage Control Knob for 30s to enter MENU mode.
  • Page 7: Analogue Remote Control Mode

    8. ANALOGUE REMOTE CONTROL MODE There are two methods for remote control of current and voltage adjustment. Both methods require both the current remote control part and the voltage remote control part to be set up and be in used at the same time in order for analogue remote control mode to be functional. Otherwise unit will be in CC mode all the time and the analogue remote control will not be functional.
  • Page 8: Remote Output On/Off Control

    8.2 Method B Using two 0 – 5K Ohm variable resistors Two variable resistors must be set up at the same time in order for the remote control to be functional. Remark: variable resistors 5Kohm. Remote Socket Pin Assignment for variable resistor FUNCTIONS REMARKS Internal DC +5V...
  • Page 9: Faults And Troubleshooting

    9. FAULTS AND TROUBLE SHOOTING 9.1 OUP: Over Voltage Protection This unit has a built-in tracking over voltage protection feature. In the event of output voltage becoming greater than the set value (see specified range from specifications table), protection will be triggered and the output power will be cut off and OUP warning appears as below.
  • Page 10: Specifications

    SPECIFICATIONS Models HCS-3400 HCS-3402 HCS-3404 Output Variable Output Voltage 1 - 16VDC 1 - 32VDC 1 - 60VDC Variable Output Current 0 - 40A 0 - 20A 0 - 10A Voltage Regulation Load (0-100% Load) 50mV Line (170-264VAC Variation) 20mV...