4. CONNECTION
4.1 This series has 2 models. Make sure you have purchased the correct one.
They have different output voltage range and current as following:
Model Number
SPS - 9600
SPS - 9602
4.2 Check the rating label of the power supply and make sure it complies with your AC mains voltage.
Connect the power supply to the AC Mains using the provided power cord.
Steps 4.3 & 4.4 explain how to use the special features: remote sensing and remote control.
You can use the 2 features at the same time or separately.
Please go to step 4.5 if you do not use the 2 features and make sure the remote control
ON/OFF switch is in OFF position(rear panel).
4.3 REMOTE SENSING – Take note of the warning and follow the order of installation.
Warning!:Never short the Remote Sensing Terminal
Connection:
1. First complete the power connections between power supply and equipment.
2. Check and make sure the power connections are secure.
3. Then make connections between Remote Sensing and equipment.
Warning!:Never short the Remote Sensing Terminal
Dis-connection:
1. First disconnect the remote sensing connections.
2. Then disconnect the power connections between the power supply and equipment.
Fig 3 showing connections between Remote Sensing, Power output and Equipment.
The remote sensing wire should be AT LEAST 22AWG wire size.
4.4 REMOTE CONTROL
4.4.1 VOLTAGE REMOTE CONTROL
Set up the provided remote connector plug
(a) Remove the black portion of the remote control connector plug by removing the screw as Fig 4.
1. Remove the screw
Output Voltage Range
1 ~ 15V
1 ~ 30V
2. Rotate the black portion
Total Rated Current (Main+Auxiliary)
60A
30A
Black portion
Fig. 4
Silver portion

Advertisement

loading

This manual is also suitable for:

Sps-9602