Jenn-Air MGS8800PZ Owner's Manual page 10

Slide-in gas ranges
Table of Contents

Advertisement

Available languages

Available languages

Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm)
countertop height.
IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood
combination installation instructions for dimensional clearances above the cooktop surface.
NOTE: When installed in a slide-in cutout, the front of oven door may protrude beyond the base cabinet.
Slide-In Cutout
A. For minimum clearance to top of cooktop, see NOTE*.
B. 13" (33 cm) maximum upper cabinet depth
C. 30" (76.2 cm) minimum opening width
D. 18" (45.7 cm) upper side cabinet to countertop
E. 30" (76.2 cm) minimum opening width
F.
5" (12.7 cm) minimum clearance from both sides of range to side wall
or other combustible material
G. The shaded area is recommended for installation of rigid gas pipe and
grounded outlet.
H. 13
1
/
" (33.3 cm)
8
I.
7
11
/
" (19.5 cm)
16
J.
4
13
/
" (12.2 cm)
16
K. 3
11
/
" (9.4 cm) plus measurement of N
16
L.
12" (30.5 cm)
M. Cabinet door or hinges should not extend into the cutout.
N. Remaining counter depth should not exceed 2
*NOTE : 24" (61.0 cm) minimum when bottom of wood or metal cabinet is shielded by not less than 1/4" (6.35 mm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood
or metal cabinet.
10
A. For minimum clearance to top of cooktop, see NOTE*.
B. 13" (33 cm) maximum upper cabinet depth
C. 30" (76.2 cm) minimum opening width
D. 18" (45.7 cm) upper side cabinet to countertop
E. 30" (76.2 cm) minimum opening width
F.
G. The shaded area is recommended for installation of rigid gas pipe and
H. 13
I.
J.
K. 3
L.
M. Cabinet door or hinges should not extend into the cutout
1
/
" (5.7 cm).
4
Front Control Cutout
5" (12.7 cm) minimum clearance from both sides of range to side wall
or other combustible material
grounded outlet.
1
/
" (33.3 cm)
8
7
11
/
" (19.5 cm)
16
4
13
/
" (12.2 cm)
16
11
/
" (9.4 cm)
16
12" (30.5 cm)