SAFETY STATEMENTS

1) This device will not serve as a cure of any symptoms of your heart disease. The measuring
data is only for reference. Always consult your attending physician if any measuring results
are abnormal.
2) Never use the device if it malfunctions, if it fell to the ground and got damaged or if it fell into
water. In these cases bring the device to a specialised service to have the safety and func-
tions of the device checked.
3) Never immerse the device in water or other liquids! Prevent water from entering the device.
4) Do not place the device on hot heat sources (e.g. stove, cooker, heating etc.) or near con-
tainers with water (e.g. washbasin, sink).
5) Handle the device with care, protect it from impacts, dust, chemicals, sweat, toiletries, cos-
metics and big temperature changes.
6) Never expose the device to direct sunlight or heat sources, low or high temperatures, or
excessive moisture (please see chapter on TECHNICAL SPECIFICATIONS).
7) If the device has been stored at lower temperatures, let it acclimate to room temperature
before use.
8) Always follow the operation procedures described in the instruction manual. Be sure to
store well this manual for future reference. Consider the instructions in the manual to be a
part of the device and pass them on to any other user of the device.
9) The device can only be used by people with the circumference of the arm within the (min./
max.) range of the arm cuff.
10) Do not put the device into operation unless the cuff has been properly applied and fastened
on the arm.
11) Do not inflate the arm cuff without it being wrapped on the arm.
12) Do not wrap the arm cuff and air tube around the neck as there is a danger of suffocation.
Do not insert the air tube into a body orifice.
13) When disconnecting the air tube from the device never pull at the arm cuff or the air tube,
only at the air tube end piece.
14) Measurements may be affected if the device is used close to television, LCD monitor, micro-
wave oven, mobile phone, X-ray or any other device with strong electrical / magnetic field.
15) Do not use the device on children, legally incapacitated people or persons who cannot
express their feelings.
16) Use only accessories intended for this particular type of device. The use of unauthorised
accessories may cause incorrect measurements, malfunctioning or injuries.
17) Do not dismantle the device or remove any of its components.
18) The manufacturer is not liable for damages caused by mishandling the device (e.g. damage
to health or the device). The use of this device does not substitute medical care.
19) The battery liquid may leak and damage the main device. Please observe the following points:
* When you are not going to use the device for a longer period of time (approximately three
months or more), take out the batteries.
* Replace the worn batteries with new ones immediately.
* Do not use worn and new batteries together.
* Do not insert the batteries with their polarities in wrong direction.
* Do not use rechargeable accumulators.
* Dispose of the discharged batteries in an appropriate manner (please see chapter
on the disposal of batteries).
* Keep the batteries out of the reach of children or legally incapacitated people.