Message:
1210 – Drive motor fault
Wheel stuck
Possible cause:
– Overload at a drive wheel
Remedy:
– Clean robotic mower (
16.2)
– Level out any uneven areas (holes,
depressions) in mowing area
Message:
1220 – Rain detected
Mowing interrupted
Possible cause:
– Mowing operation has been interrupted
or not started due to rain
Remedy:
– No action necessary; adjust rain sensor
if required (
11.11)
Message:
1230 – Docking error
Dock iMOW®
Possible cause:
– Docking station has been located,
automatic docking not possible
Remedy:
– Check docking, if necessary dock
robotic mower manually (
– Check perimeter wire – ensure correct
routing in area of docking station
(
9.9)
0478 131 9963 F - EN
Message:
2000 – Signal problem
Dock iMOW®
Possible cause:
– Wire signal faulty, fine tuning necessary
Remedy:
– Place robotic mower in docking station
– then press OK
Message:
2020 – Recommendation
Annual service by spec. dealer required
Possible cause:
– Machine service recommended
Remedy:
– Have the annual service carried out by
a STIHL specialist dealer
Message:
2030 – Battery
Allowed operating time reached
Possible cause:
– Battery replacement necessary
Remedy:
– Have the battery replaced by a STIHL
specialist dealer
Message:
15.6)
2031 – Charging failure
Check charging contacts
Possible cause:
– Charging cannot be started
Remedy:
– Check docking station and robotic
mower charging contacts and clean if
necessary – then confirm message with
OK
Message:
2032 – Battery temperature
Outside temperature range
Possible cause:
– Temperature in battery during charging
too low or too high
Remedy:
– Allow robotic mower to warm up or cool
it down – observe permissible
temperature range of battery
Message:
2040 – Battery temperature
Outside temperature range
Possible cause:
– Temperature in battery when starting
mowing operation too low or too high
Remedy:
– Allow robotic mower to warm up or cool
it down – observe permissible
temperature range of battery (
Message:
2050 – Adapt mowing plan
Extend active times
Possible cause:
– Active times have been
shortened/deleted or the mowing
duration has been extended – the
stored active times are insufficient for
the necessary mowing operations.
Remedy:
– Extend the active times (
shorten the mowing duration (
6.4)
11.7) or
11.7)