Candy CH64FC User Instructions page 12

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
Heater d splay
F0
Fc
Ft
FE
Fb
FU / FJ
FA
FC / Fd
Fr
"Val d only for Cyprus"
Fault
Touch control software error.
Touch control zone is too hot
and has turned off all the
heaters.
Touch control temperature
sensor can be damaged.
Touch control temperature
sensor can be damaged.
Excessive sensitivity
on any key.
Security keyboard error
Security software error
Security software error
Relays security error
Act on
If error has occurred disconnected and connect again the cooktop to the power supply. If error persist,
call after-sales service. If error appears suddenly in a normal operation, call after-sales service.
Wait until temperature goes down. Cook-top will automatically recovered when temperature
reaches a normal value.
Wait until temperature goes down. If message persist when temperature reaches an environment
value, call after-sales service.
Wait until temperature goes down. If message persist when temperature reaches an environment
value, call after-sales service.
See if cook-top is mounted correctly. Be sure that keys touch correctly the glass surface.
This error is a keyboard auto-check. It disappears when autocheck return to secure value. If error
persist, call after-sale service.
This error is a software auto-check. It disappears when auto-check return to secure value. If error
persist, call after-sale service.
This error is a software auto-check. It disappears when auto-check return to secure value. If error
persist, call after-sale service.
Any relay driver can have any problemn. Remove cook-top from the power supply, wait a minute
and switch on again. If error persist, call after-sale service.
10 GB

Advertisement

Table of Contents
loading

Table of Contents