Dc Characteristics - Newland NLS-EM3396 V2 Integration Manual

Oem scan engine
Table of Contents

Advertisement

DC Characteristics

Operating Voltage/Current
Ta=25° C
Parameter
Operating Voltage
Current (@3.3V)
Note:
Enter standby mode: nls0302080; stop decoding.
Standby mode: no decoding and the rest are same as the running mode.
Enter sleep mode: nls0302081; any interrupt can be wake up the device.
Sleep mode: peripherals are turned off except for communication interface and keys.
Enter deep sleep mode: nls0302082; only the nTrig key rising edge can wake up the device.
Deep sleep mode: peripherals are turned off except for keys and rising edge can wake up the device.
9
Description
VDD
Operating Current
Standby Current
Sleep Current
Minimum
Typical
3.15
3.30
-
-
Maximum
Unit
3.45
V
195
mA
9.1
mA
100
uA