PFC 45 - PFC 60 - PFC 90 – PFC 120
Diagnostic aid
JS
1. Symptom
The boiler remains on standby:
-
A heating demand is present (symbol
-
No fault displayed.
The boiler doesn't start
-
2. Solution
1) Switch the boiler off and on again (ON/OFF switch)
2) If the default E07.12 is displayed:
- the safety thermostat is activated,
- the RV safety control box displays a E2 fault, stops the boiler, but does not
immediately transmit the fault to the boiler control panel (no error displayed). The
display of the error only appears after switching the boiler off and on again.
Labo
N° IT2721-en
is blinking)
Symbol
Boiler in demand
1/2
is blinking:
RV Safety control box
EN
07/07/2023
IT2721-en

Advertisement

loading

Summary of Contents for DeDietrich MODULENS O PRO

  • Page 1 Technical Information MODULENS O PRO PFC 45 - PFC 60 - PFC 90 – PFC 120 Diagnostic aid N° IT2721-en 07/07/2023 1. Symptom The boiler remains on standby: A heating demand is present (symbol is blinking) No fault displayed. The boiler doesn't start...
  • Page 2 3) Solve the E07.12 fault: 3.1 Carry out the checks indicated in the instruction manual to remove the fault: E07.12 STB activated No water circulation Vent the air from the heating system • Check the circulation (direction, pump, • valves) Check the water pressure •...