Bristan GLR 1/2 C Installation Instructions Manual
Bristan GLR 1/2 C Installation Instructions Manual

Bristan GLR 1/2 C Installation Instructions Manual

Glorious tap range

Advertisement

Quick Links

Installation Instructions
Glorious Tap Range
Models covered:
GLR 1/2 C, GLR 3/4 C, GLR BAS C,
GLR WMBAS C, GLR WMBF C,
Please keep this booklet for future
reference.
Installer, when you have read these
instructions please ensure you leave them
with the user.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GLR 1/2 C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bristan GLR 1/2 C

  • Page 1 Installation Instructions Glorious Tap Range Models covered: GLR 1/2 C, GLR 3/4 C, GLR BAS C, GLR WMBAS C, GLR WMBF C, Please keep this booklet for future reference. Installer, when you have read these instructions please ensure you leave them...
  • Page 2: Table Of Contents

    Contents Thank you for choosing Bristan, the UK’s leading taps and showers expert. We have designed this product with your enjoyment in mind. To ensure that it works to its full potential, it needs to be fitted correctly. These fitting instructions have been created to give you all of the information you need and, if you need any further help, please do not hesitate to contact us.
  • Page 3: Important Safety Information

    Important Safety Information • Please read these instructions thoroughly and retain for future use. • All products manufactured and supplied by Bristan are safe provided they are installed, used correctly and receive regular maintenance in accordance with these instructions. •...
  • Page 4: General Information

    For further details contact your Local Water Authority. Specifications Working pressure Product Code Inlet GLR 1/2 C 1/2" BSP Threaded Tail GLR 3/4 C 3/4" BSP Threaded Tail GLR BAS C M10 15mm Compression Flexible Tails...
  • Page 5: Dimensions

    Dimensions Basin Taps 102.7 32.7 G 1/2 Bath Taps 111.3 32.7 112.8 56.4 G 3/4 Dimensions are approximate and in millimetres. Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
  • Page 6 Dimensions Cont. Basin Mixer 191.5 144.2 110.1 G 1/2 Wall Mounted Basin Mixer 14.5-24.5 G 1/2 79.3 242.5 Dimensions are approximate and in millimetres. Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
  • Page 7 Dimensions Cont. Wall Mounted Bath Filler 17.5-27.5 G 3/4 79.3 202.5 Dimensions are approximate and in millimetres. Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
  • Page 8: Installation Requirements

    Installation Requirements Flexible Connecting Pipes Care must be taken when connecting the flexible connection pipes to the household pipework to ensure they do not bend sharply and kink or twist. See below for recommended ways to fit the flexible connecting pipes. Slight 90°...
  • Page 9: Installation

    Installation Basin Mixer 1. Screw the flexi tails into the bottom of the body by hand only (DO NOT OVERTIGHTEN). 2. Feed the flexi tails through the hole in the basin ensuring the washer is fitted between the tap body and fixing surface to ensure a water tight seal.
  • Page 10: Basin & Bath Taps

    Installation Cont. Basin / Bath Taps 1. Slide the plinths onto the threaded tails of the taps. Fit the tap bodies to the basin/ bath ensuring that the washers are fitted between the plinths and the basin / bath to create a water tight seal.
  • Page 11: Wall Mounted Basin Mixer / Bath Filler

    Installation Cont. Wall Mounted Basin Mixer / Bath Filler 1. Decide on the final position of the basin mixer/ bath filler. Install suitable battons into the wall cavity if required to support the tap body. 2. Plumb the hot and cold water supply pipes to the required position.
  • Page 12: Maintenance

    If necessary replace the valve using parts supplied by Bristan. Important: Tighten the valve with Lightly grease the seal (only use silicone the correct size socket and apply grease), replace the valve, shroud cover and appropriate force/torque.
  • Page 13: Troubleshooting

    Troubleshooting Symptom Cause Remedy No flow or low Partially closed isolation valve. Open isolation valve. flow rate Instantaneous water heater Increase water flow rate or cycles on and off as flow rate or pressure through system to pressure is too low. meet required minimum working pressure of tap.
  • Page 14: Guarantee

    Guarantee At Bristan, we want to make things as • Repair under this guarantee does not easy as possible for our customers. That’s extend the original expiry date. The why we design products that are easy to guarantee on any replacement parts or fit and use, and that are quality tested to product ends at the original expiry date.
  • Page 15 ‘phone or with a spare part, then we’ll guarantee period, contact Bristan Care send out one of our Bristan Care Customer Service on 0844 701 6273 with engineers to take a look. Bristan Care...
  • Page 16 GLR BOOK 1 Part Numbersa: Issue: D1 Useful contact details: Customer Service: 0844 7016273 Bristan Group Ltd. Customer Service Email: Birch Coppice Business Park Customercare@bristan.com Dordon Tamworth Customer Service Fax: Staffordshire 0844 7016275 B78 1SG Reception: Web: www.bristan.com 0844 7016274 Email: enquire@bristan.com...

This manual is also suitable for:

Glr 3/4 cGlr bas cGlr wmbas cGlr wmbf c

Table of Contents