6.3

Door

In order for the insert to burn at its best efficiency, the door must provide a perfect seal with the
firebox. Therefore, the gasket should be inspected periodically to check for a good seal. The
tightness of the door seal can be verified by closing and latching the door on a strip of paper.
The test must be performed all around the door. If the paper slips out easily anywhere, either
adjust the door or replace the gasket.
6.3.1
Adjustment
The gasket seal may be improved with a simple latch mechanism adjustment:
1.
Remove the split pin by pulling and turning it using pliers.
2.
Turn the handle one counterclockwise turn to increase pressure.
3.
Reinstall the split pin with a small hammer.
Figure 18: Removing the split pin
Figure 17: Door gasket seal verification
Figure 19: Installing the split pin