Empire Comfort Systems WB17IN Installation And Operation Manual page 36

Insert
Table of Contents

Advertisement

The dealer may offer a liner fastening system, sold separately. Follow the installation instructions
provided with the liner fastening system.
Figure 30: Liner fastening system
10.5.2 Liner Offset Adapter
A liner offset adapter, sold separately, can also be installed. This should only be installed if no
other option is possible and if the total height of the fireplace and chimney is at least 20 feet.
This kind of adaptor is restricting the free flow of exhaust gases and may result in smoke roll-
out from the insert when the door is open for reloading. When installing a liner offset adapter,
secure the three brackets provided in the user manual on top of the insert. The long end of the
brackets must be attached to the insert. Then, follow the instructions in the manual provided
with the liner offset adapter kit.
Figure 31: Securing the brackets
Figure 32: Offset liner adaptor
Page 36

Advertisement

Table of Contents
loading

This manual is also suitable for:

Archway 1700

Table of Contents