Download Print this page

MrCool DIY-12-HP-WM-115C25 Quick Start Manual page 3

4th gen do-it-yourself ductless mini-split heat pump a/c

Advertisement

STEP 3 - Continued
4. Snap the air handler onto the wall bracket by leaning the
top towards the wall and hooking it on the top of bracket.
Then, apply pressure to the bottom half to snap it to the
bracket.
STEP 4 - Outside
1. Place outside condenser unit firmly on the ground or
attach it to a secure metal wall bracket or pad. A drain pipe
underneath the unit is not required unless the unit is
elevated. Please refer to the manual for more information.
Minimum Clearance
on the left side of unit:
12 in (30 cm)
Minimum Clearance
above unit:
24 in (60 cm)
Minimum Clearance
on the right side of unit:
24 in (60 cm)
STEP 4 - Continued
2. Install the wall hole finishing cap/seal. Then, carefully
bend the piping coming out of the exterior wall hole (from
the indoor unit) down towards the wall.
3. Remove the plastic seals from the indoor handler
refrigerant lines.
4. Carefully unroll one end of the Quick Connect® line set*.
Only unroll the amount needed to connect to the indoor
handler fittings. Leave the remainder coiled.
5. Align the Quick Connect
set to the matching indoor handler fittings. Tighten the first
few threads by hand.
6. Using two open-ended wrenches, or crescent
(adjustable-type) wrenches, and the image below as a
guide: place the wrenches on points marked "1" & "2," only
turning the nut at the point marked "2." Ensure that the
screw connector does not become crooked while working
quickly to tighten it. Tighten the connector until snug.
7. Then, tighten the connector slightly beyond that point to
apply torque to the connector. Repeat the same steps for
the second line. Please refer to the manual for information
about torque requirements for the connectors.
*Pat. https://mrcool.com/mrcool-patents/
fittings of the refrigerant line
®

Advertisement

loading

This manual is also suitable for:

Diy e star series