Troubleshooting; Dépannage - Hans Grohe Aquno Select M81 250 2jet 73836 1 Series Installation/User Instructions/Warranty

Hide thumbs Also See for Aquno Select M81 250 2jet 73836 1 Series:
Table of Contents

Advertisement

Troubleshooting

Problem
SatinFlow too low / little water
Diverter to SatinFlow is stuck
Faucet dripping
To little water at the pull-out spout
Water escaping at the threaded
base
Pull-out length hose too short (less
than 19" (500 mm))
Dépannage
Dysfonctionnement
SatinFlow trop faible / peu d'eau
Le passage sur SatinFlow coince
Le mitigeur goutte
Trop peu d'eau au niveau du bec
extractible
Fuite à la fixation sous le mitigeur
Longueur d'extraction du tuyau
trop courte (inférieure à 500 mm)
20
Possible Cause
– Nozzles and / or flow restrictor
dirty / calcified
– Diverter button fouled
– Cartridge dirty or worn
– Check valves in the sprayhead
and faucet aerator dirty or
calcified
– Connection hoses not complete-
ly screwed into body of faucet
– Hose weight positioned incor-
rectly
Origine
– Buses et / ou limiteur de débit
sale / entartré
– Bouton d'inversion encrassé
– Cartouche défectueuse
– Les clapets anti-reflux ou/ et le
régulateur de jet sont entartrés /
encrassés
– Les flexibles de raccordement
ne sont pas correctement visser
dans le corps.
– Le poids du tuyau est mal
positionné
Solution
– Remove and clean the nozzles
and flow restrictor.
– Remove and clean the diverter
button
– Replace the cartridge
– Clean the check valves and faucet
aerator
– Tighten connection hoses by hand
– Reposition the hose weight - see
page 11
Solution
– Démonter et nettoyer les buses et
le limiteur de débit.
– Enlever et nettoyer le bouton
d'inversion
– Changer la cartouche
– Nettoyer les clapets anti-reflux et
le régulateur de jet
– Resserrer le flexible à la main.
– Monter le poids du tuyau con-
formément aux instructions de
montage - voir page 11

Advertisement

Table of Contents
loading