13.
Clean and braze the refrigeration connections at the evaporator inlet and outlet using silver brazing
solder. Be careful to protect the expansion valve with a cold wet rag or a commerical heat protction
product.
14.
Install the new ¼" dryer in the liquid line.
15.
Pressure test the system for leaks with dry nitrogen.
IMPORTANT: Do not exceed the nameplate pressure ratings!
16.
Evacuate the system to at least 500 microns.
17.
Re-charge the system using a refrigerant scale or a Dial-a-Charge to the exact nameplate
specifications.
18.
Re-insulate the refrigeration lines.
19.
Install the dispense tray assembly with the new clamp and re-connect the water feed line.
20.
Disassemble the auger assembly and inspect the bearings. Replace if necessary. Reassemble the
auger assembly. Place the auger assembly into the evaporator and replace the dispense tray cover.
21.
Restore the water supply and check for any leaks. Ensure that the evaporator fills to the correct
level. Adjust the float mechanism as required. Confirm that the float mechanism shuts off
completely once the correct water level is achieved.
22.
Restore the power supply and ensure that the incoming voltage is within the nameplate ratings.
Confirm that the gear motor amp draw is within its nameplate rating. Refrigerant suction pressure
should settle at approximately 28 psig (R404-A).
23.
Confirm that the icemaker is operating properly and replace the exterior panels.
Publication Number: 620516354INS
- 2 -
© 2008, IMI Cornelius Inc.