9.4
Desiccant
Desiccant
Volume profile
Charge per tower (Cartridge)
9.5
Condensate
Condensate separator connection (pre-filter)
9.6
Measurements, Weights
Height / Width / Depth
Weight
9.7
Nominal Air Flow
Model
DTP [°F]
DSHD-7
- 40
DSHD-13
- 40
DSHD-18
- 40
DSHD-21
- 40
DSHD-27
- 40
DSHD-40
- 40
DSHD-7
- 94
DSHD-13
- 94
DSHD-18
- 94
DSHD-21
- 94
DSHD-27
- 94
DSHD-40
- 94
1) According to CAGI (Compressed Air and Gas Institute) standard
ADF-200, Dual Stage Regenerative Desiccant Compressed Air
Dryers - Methods for Testing and Rating. Conditions for rating
dryers are: inlet pressure - 100 psig (7 kg/cm
- saturated at 100°F (38°C)
9.8
Correction Factors
Working pressure (psi)
Working pressure (bar)
K
p(ü)
Correction factor for compressed air inlet temperature
Compressed air inlet temperature (°F / °C)
k
Tin (DTP = -40°C/ °F)
16
DSHD-7
gal
0.68
lb
4.10
DSHD-7
DSHD-7
inch
lb
61.3
Max. air flow inlet [scfm]
7
13
18
21
27
40
5
9
12
14
18
27
); inlet temperature
2
Correction factor for working pressure
58
72
87
100
4
5
6
7
0.40
0.57
0.77
1.00
86 / 30
1.07
DSHD-13
DSHD-18
Activated alumina
0.99
1.37
6.13
8.71
DSHD-13
DSHD-18
See filter instruction manual
DSHD-13
DSHD-18
See dimensional drawing
77.2
97.4
1
116
131
145
8
9
10
1.13
1.25
1.38
95 / 35
100 / 38
104 / 40
1.07
1.00
0.93
DSHD-21
DSHD-27
DSHD-40
1.75
2.32
11.35
14.88
DSHD-21
DSHD-27
DSHD-40
DSHD-21
DSHD-27
DSHD-40
117.7
136.2
160
174
189
203
11
12
13
14
1.38
1.50
1.56
1.61
113 / 45
122 / 50
0.82
0.72
2.97
19.29
165
218
15
1.67
Need help?