b. Connect the drain hose to a minimum
height of 40 cm and a maximum height of
100 cm.
c. Installing the water draining hose at
ground level or close to the floor (40 cm
below) and then raising it makes water
discharge difficult and the laundry may
come out extremely wet. Thus, follow the
heights provided in the figure.
d. To prevent the waste water to go back
into the product again and to ensure easy
drainage, do not immerse the end of the
hose into the waste water or do not insert
it into the drain for more than 15 cm. If it
is too long, cut it short.
e. The end of the hose should not be bent,
it should not be stepped on and the hose
must not be pinched between the drain
and the product. Otherwise, water dis-
charge issues may emerge.
f. If the length of the hose is too short, use
it by adding an original extension hose.
The length of the hose shall not be longer
than 3.2 m. To prevent water leaks, al-
ways secure the connection between the
extension hose and the draining hose of
the product with a suitable clamp so that
it does not come off and cause leaks.

4.6 Adjusting the Stands

NOTICE
In order to ensure that the product
operates more silently and vibration-
free, it must stand level and bal-
anced on its feet. Ensure that the
product is balanced by adjusting the
feet. Otherwise, the product may
move from its place and cause
crushing, noise and vibration prob-
lems.
To avoid damaging the lock nuts, do
not use any tools to loosen the nuts.
a. Loosen the lock nuts on the feet by hand.
b. Adjust the feet until the product stands
level and balanced.
c. Tighten all lock nuts again by hand.

4.7 Electrical Connection

Connect the product to a grounded outlet
protected by a 16 A fuse. Our company shall
not be responsible for the damages that
shall be incurred due to using the product
without grounding according to local regula-
tions.
• Connection must comply with national
regulations.
• The electrical connection cable infrastruc-
ture of the product must be adequate and
suitable for product requirements. It is re-
commended to use a residual current
device.
• Power cable plug must be within easy
reach after installation.
• If the current supply to the fuse or breaker
in the house is less than 16 Amps, have a
qualified electrician install a 16 amp sup-
ply.
• The voltage specified in the "Technical
specifications" section must be equal to
your mains voltage.