Electrical connection

The coffee machine is supplied with a
mains cable and moulded plug ready
for connection to a suitable earthed
socket.
The socket must be easily accessible
after the coffee machine has been
installed. If the socket is not easily
accessible, ensure that a suitable
means of disconnection for each pole is
provided on the installation side.
Risk of fire from overheating.
Connecting the coffee machine to
multi-socket adapters or extension
cables can overload the cables.
For safety reasons, do not use multi-
socket adapters, extension cables,
adapters and/or energy-saving
plugs.
The electrical system must comply with
local and national safety regulations
(BS 7671 in the UK).
For safety reasons, we recommend
using a type  residual current device
(RCD) in the relevant electrical
installation for connecting the coffee
machine.
If the mains connection cable is
damaged, it must only be replaced with
a specific mains connection cable of
the same type (available from the Miele
Customer Service Department). For
safety reasons, such replacement may
only be carried out by a qualified
specialist or the Miele Customer
Service Department.
The data plate indicates the nominal
power consumption.
The fuse rating must be at least 10 A.
Compare this information with the data
of the on-site electrical connection. If in
any doubt, consult a qualified
electrician.
Temporary or permanent operation on
an autonomous power supply system or
a power supply system that is not
synchronised with the mains power
supply (e.g. island networks, backup
systems) is possible. A prerequisite for
operation is that the power supply
system complies with the specifications
of EN 50160 or an equivalent standard.
The function and operation of the
protective measures provided in the
domestic electrical installation and in
this Miele product must also be
maintained in isolated operation or in
operation that is not synchronised with
the mains power supply, or these
measures must be replaced by
equivalent measures in the installation.
As described, for example, in the
current version of VDE-AR-E 2510-2.