Receiver compatible with the X2 TECHNOLOGY system and system 300.
It can accommodate the loudspeaker YAL to make the call note more powerful.
It features the following controls:
![]() | Door lock release (1) |
![]() | Auxiliary |
(1) This control can only be used if the unit is on.
By using actuators VLS/300 or customizing control unit XA/300LR by means of programmer PCS/300, you can have the control enabled at all times.
Terminal block M1 (fig. 5)
![]() | line |
![]() | personal door-bell |
![]() | connection for YAL loudspeaker |
Normally supplied ready inserted. Remove the jumper SW1 (fig. 5) in the event the volume of the call note is to be attenuated, or if you have a number of receivers activated by the same call. Maximum number of receivers activated by same call:
Loudspeaker YAL should be considered as a receiver.
The receiver is fitted with a differentiated call input (terminal ) (i.e.: for personal door-bell) a continuous tone call (approximately 2 s).
First, remove the housing (fig. 1) and fasten the base directly to the wall (fig. 2) or to the embedding box (fig. 3 or 4). If walls are not perfectly level, do not overtighten screws.
In installations with XA/300LR we recommend you gather up the receiver's ID (SN) codes, applied on the outside of the housing, and enter them in the tables that come with the XA/300LR and IPC/300LR.
When programming the unit through the PCS/300 unit, use the dedicated profile for the XC/300 receiver.
BPT S.p. A.
Via Cornia, 1
33079 Sesto al Reghena-PN-Italy
info@bpt.it – www.bpt.it