Hydraulic Configuration; 10.2.1 Explanations To The Hydraulic Configuration - Bosch Compress 5800i AW Installation Instructions Manual

Indoor unit for air to water heat pump
Hide thumbs Also See for Compress 5800i AW:
Table of Contents

Advertisement

Technical information and reports
Integrated buffer cylinder volume
Type of circulation pump PC1
Low energy pump
Nominal flow rate
Residual head
Minimum flow during defrosting
Maximum operating pressure
Minimum operating pressure
Maximum water temperature (flow), booster heater only
Minimum water temperature if cooling is available
Connection (Cu)
Connection heat transfer medium (Cu)
Expansion vessel
Heat transfer medium
Circulation pump type PC0
Low energy pump
Nominal flow rate
General
Waste water connection
IP-Rating
Dimensions (width x depth x height)
Weight excluding packaging
Installation height
1) Recommended value for the most effective pumps: EEI ≤ 0.20
2) The flow rate and residual head depend on the connected heat pump or in case of hydraulic separation. See table 15 and the circulation pump diagram.
3) The flow rate and residual head depend on the connected heat pump and pipe dimensions (  chapter 5.2).
Heat pump
Nominal flow
underfloor heating
(l/s)
4
0,21
5
0,29
7
0,34
Table 15 Nominal flow heating system
10.2

Hydraulic configuration

The product must only be installed according to the manufacturer's
official system solutions. Other system solutions are not permitted.
Liability is voided in the case of damage and problems resulting from
impermissible installation.

10.2.1 Explanations to the hydraulic configuration

General
XCU-THH (XCU
Installer module integrated into the indoor unit
HY)
UI800
User interface
CR10
Room controller (accessories)
WP/WD/WH
Buffer cylinder (accessories)
MD1
Condensate sensor (accessories)
T1
Outside temperature sensor
PW2
DHW circulation pump (accessories)
TW1
DHW temperature sensor
34
Unit
l
l/s
kPa
l/min
kPa/bar
kPa/bar
°C
°C
mm
mm
l
l/s
mm
IP
mm
kg
m
Nominal flow
radiator (l/s)
PC1
MC1
0,15
0,17
0,20
3
16
Grundfos UPM4L K
1)
EEI ≤ 0.20
2)
2)
15
300/3
70/0,7
60
7
Ø 28
Ø 28
17
Grundfos UPM4L K
1)
EEI ≤ 0.20
3)
Ø 22
X1D
600 x 600 x 1787
156
Up to 2000 m above sea level
Heating circuit without mixing valve
Circulation pump for heating circuit
Safety thermostat
Compress 5800i AW – 6721858460 (2023/06)