Choosing a Location

• Choose a location so that the sensor can "see" all paths of movement.
• The sensor may be wall or ceiling mounted.
• As distance from the sensor increases, it takes more movement to be
detected. For example: a half-step will register at ten feet, but not at 40
feet. 40 feet will need several steps for detection.
How does the LED Detection
Indicator work?
The red LED above the lens shows
the logic state of the sensor. If the
sensor is set for night-only
operation, the LED will go on for
daytime detections without turning
on the lights. Except during
detections, which trigger the
controlled lights, at night the LED
remains on and serves as a
deterrent, indicating a security
device in operation.
How large of an area does
STEALTH detect?
The standard lens detection pattern
extends out 50' and is 100° wide. The
sensor may be swiveled in any
direction to cover the area desired.
Always keep the sensor level to
ensure full coverage. To reduce
coverage tilt the sensor down.
STEALTH STL100 comes with a stan-
dard "Double Look Down" Lens. This
lens has one "Look Out" zone and
two "Look Down" zones for excellent
detection at both long and short
range.
3
Red LED Detection Indicator
Detection Pattern

Wiring Diagrams

Basic Wiring Diagram
White
Ground
Power In
Red
Black
Sensor
Basic Kit Wiring Diagram
Note: Pigtail is only used to switch
remote or additional light fixtures.
Red
(pigtail)
Black
Red
Black
Power In
White
White
Ground
Ground
Red pigtail only used to switch remote or additional xtures
Power Quality
It is not recommended to install
sensors on a circuit that also feeds
motor loads such as HVAC equipt-
ment, kitchen appliances, or garage
door openers. The STEALTH circuit is
surge and transient protected to IEC
specifications. However, if voltage
varies significantly from
277 volts,
sensor may malfunction.
4
Multiple Fixtures
• Multiple fixtures may be wired to
a single sensor
• To handle loads greater than
300W watts, a qualified
electrician should install a relay.