Technical data

Problem
The display shows
"Error 52"
The display shows
"Error 60"
The display shows
"Error 61"
12
Technical data
Dimensions (width x height x depth):
Weight:
Power supply:
Refrigerant extraction rate:
Vacuum pump output:
Hermetic compressor output:
Drier filter output:
Filling cylinder accumulator capacity:
Noise emission:
Accuracy of the electronic scale for refrigerant:
Accuracy of the electronic scale for old/new oil/
UV additive:
Operating temperature:
118
Cause
No USB stick was found/rec-
ognised
During the hybrid service
(flushing the service hoses
with hybrid oil), a vacuum
could not be achieved.
Pressure increase during the
hybrid service .
AirConServiceCenter
Remedy
Insert the USB stick.
Make sure that the USB stick
has been formatted with the
FAT32 file system.
Are the service hoses con-
nected to the hybrid flush
container?
Is the hybrid flush container
fitted the right way round?
Check the connections for
leaks.
Are the service hoses con-
nected to the hybrid flush
container?
Is the hybrid flush container
fitted the right way round?
Are the service couplings
open?
AirConServiceCenter
ASC1000G
560 mm x 1300 mm x 650 mm
95 kg
230 V/240 V – 50 Hz/60 Hz
18 kg/h
4 cars/h
0.2 kW
150 kg
12.0 l/10.0 kg
55.5 dB (A)
± 10 g
± 1 g
+ 5 °C – + 45 °C
EN