A12C
7.
Screw the sealing cap onto the condensate water drain (12).
The FL indication on the segment display (29) will go out, as soon as the condensate has been
drained.
ACTIVITIES REQUIRED AFTER MAINTENANCE
If you want to continue using the device:
Leave the device to rest for 12 to 24 hours, so the refrigerant can
accumulate within the compressor. Wait 12 to 24 hours before
switching the device back on! Acting contrary might lead to
compressor damage and a malfunctioning device. If so, any
warranty claims will be voided.
Reconnect the device to the mains.