Inlet Line; Line, Inlet; Piping, Control - Gardner Denver EDF-KB Operating And Service Manual

Table of Contents

Advertisement

Length of Inlet Line
0 to 10 Feet (0 to 3 Meters)
10 to 17 Feet (3 to 5 Meters)
17 to 38 Feet (5 to 11.5 Meters)
CONTROL PIPING – Control piping is not necessary
since the Electra–Screw
piped for the control system specified.
INLET LINE – Where an inlet line is used between the
air filter and the compressor, it must be thoroughly
cleaned on the inside to prevent dirt or scale from en-
tering the compressor. If welded construction is
HP
Model
60 HP
EDFSKB
75 HP
EDFSLB
100 HP
EDHSMB
*
Flows exceeding "Maximum Water Flow" will cause severe erosion and will void unit warranty.
FIGURE 2–5 – HEAT EXCHANGER (OIL COOLER) APPROXIMATE WATER FLOW
HP
Model
60 HP
EDFSKB
75 HP
EDFSLB
100 HP
EDHSMB
*
Flows exceeding "Maximum Water Flow" will cause severe erosion and will void unit warranty.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FIGURE 2–4 – INLET LINE LENGTHS
unit is factory wired and
HEAT EXCHANGER
Water Temperature to Heat Exchanger
Gallons/minute
60 F.
70 F.
5.0
6.2
6.9
8.6
9.2
11.5
AFTERCOOLER
Water Temperature to Heat Exchanger
Gallons/minute
60 F.
70 F.
.8
1.0
1.2
1.5
1.7
2.1
FIGURE 2–6 – AFTERCOOLER APPROXIMATE WATER FLOW
13–8–606
Same as Compressor Inlet Opening
One Size Larger Than Inlet Opening
Two Sizes Larger Than Inlet Opening
used, the line must be shot blasted and cleaned to
remove welding scale. In either case, the inlet line
must be coated internally by galvanizing or painting
with a moisture and oil–proof sealing lacquer. Up to ten
(10) feet (3 meters) in length, the inlet line should be the
full size of the inlet opening on the compressor. If an
extra–long line is necessary, the pipe size should be in-
creased according to Inlet Line Length Chart
FIGURE 2–4.
Maximum
Water Flow
80 F.
90 F.
GPM*
8.3
12.5
11.5
17.2
15.3
22.9
Maximum
Water Flow
80 F.
90 F.
GPM*
1.4
2.1
2.0
3.0
2.8
4.1
Page 11
Diameter of Pipe Size
Approx.
Water Pressure
Drop @ 90 F
Water Temp.
PSI
40.8
2.0
40.8
1.5
40.8
5.0
Approx.
Water Pressure
Drop @ 90 F
Water Temp.
PSI
26.0
Less than 1 PSI
26.0
for any flow rate
shown in the table.
26.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Edf-lbEdh-mbEdf99dEdf-lcEdh-maEdh99c ... Show all