Toshiba RAV-GV1601AT8P-E Service Manual page 107

Hide thumbs Also See for RAV-GV1601AT8P-E:
Table of Contents

Advertisement

No.
Part name
Compressor
6
Compressor lead
(Continued)
∗ Put the compressor lead wire and the
Procedure
2. Mounting of compressor
1) Mount the compressor in the reverse
procedure of removal.
NOTES:
∗ Fix the removed each sensor and PMV coil
lead wire to the discharge pipe and the
suction pipe with the bundling band via the
pipe cover.
In this time, take note that each sensor and
PMV coil lead wire do not come to contact
with the discharge pipe and the reactor.
(For fixing to the discharge pipe, use the
black heat-proof pipe cover and the bundling
band for heat-proof which is sold on the
market.)
∗ As shown in the right figure, mount the
soundproof plate (inner winding, outer
winding) by inserting between the compres-
sor and the piping, and between piping and
the partition plate.
compressor case thermo between inner
winding and outer winding of the soundproof
as if dropping them in.
Pipe cover, bundling
band, each sensor
(TL,TO,TE,TD,TS sensor)
PMV coil lead.
PMV coil lead
Discharge
pipe
plate (inner winding) through
between compressor and
discharge pipe, suction pipe
and then put it on the other
Soundproof plate
(outer winding)
Bundling band,each
Suction pipe
- 107 -
Remarks
Pass the soundproof
Pass the soundproof
plate (outer winding) through
between the suction pipe and gas
pipe and then put it on the other
side at this position
side at this position.
soundproof plate
soundproof plate
(outer winding)
sensor (TL and
TO sensors)
Suction
Pipe
Soundproof
plate (upper)
Do not make
clearance
between the
(upper)
and the