FIXED STRIKING PLATE INSTALLATION - Item + CF
70
Place the striking plate in face of the lock. Slide to close the door in
order to locate the exact position to make the proper hole into the door.
Cut a suitable hole in the door, then install the striking plate by using
suitable screws.
Adjust the extension of the locking pin: loosen the "A" screw, turn the locking
pin to adjust its extension, then tighten the "A" screw.
Item 23622S / 23624S ("FAIL SAFE"): power the lock. After the initial
peak the current consumption drops down to 300 mA. Close the door and
test the retention strength, then send the electrical unlocking command or
use the cylinder to open the door.
Item 23822S / 23824S ("FAIL SECURE"): close the door and test the
retention strength, then send the electrical unlocking command or use the
cylinder to open the door. The unlocking is obtained by providing current.
In case of opening problems: make sure that lock and counter-lock are
correctly lined up, no external objects interfere with the locking mechanism,
the supplied voltage is correct and no force stronger than 50 N is loaded
to the locking pin while sending the unlocking command.