Opera ARCA SLIDE Installation Instructions Manual page 3

Table of Contents

Advertisement

Power supply
Power consumption
Holding force
Opening overload
Pin status reporting
Close the door and verify the correct retention of the counter lock. Activate
the unlocking command and verify the release of the lock.
CAUTION
Do not pull the door open before the unlocking command.
It is recommended to verify periodically the correct locking of the
door, the unhindered reception of the opening command and the
tightening of the installed screws.
Item 23622S
Item 23822S
12 Vdc
1 A
800 kg
Max 50 N
By means of contact
COM./N.O./N.C.
INSTRUCTIONS
4
Item 23624S
Item 23824S
24 Vdc
500 mA
800 kg
Max 50 N
By means of contact
COM./N.O./N.C.

Advertisement