Airius AIR PEAR 25/EC Product Information & Installation Manual

Airius AIR PEAR 25/EC Product Information & Installation Manual

Advertisement

Quick Links

PRODUCT INFORMATION &
INSTALLATION GUIDE
2021
Airius Model 25/EC
AIR PEAR SERIES
www.airius.com.au

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AIR PEAR 25/EC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Airius AIR PEAR 25/EC

  • Page 1 PRODUCT INFORMATION & INSTALLATION GUIDE 2021 Airius Model 25/EC AIR PEAR SERIES www.airius.com.au...
  • Page 2: Warranty

    Off-White, Black or Grey available German EBM Papst EC motor 230 Volt @ 50/60 Hz ACCESSORIES & OPTIONS Airius suspended ceiling kit - Allows Airius unit to be mounted in a suspended ceiling grid OPERATING TEMPERATURES Multiple speed control options available: Min start temp (approx.)
  • Page 3: Velocity Profile

    However it is permanently mounting in the ceiling. not imperative. For Cooling the Airius fan should be located to suit client’s require- MAINTENANCE ments. Suggested locations are from just under the ceiling or closer to the floor to ensure suitable air-cooling flow.
  • Page 4 It features a removable torx head screw that can be attached to a back up chain or cable (rated @ 90 kgs). Airius Air Circulation & Destratification Fan LEASH ANCHOR POINT 10-32 X 1/4 T-25 TORX PAN HEAD...
  • Page 5 Optional Accessory For Wall Installations Warranty - 3 -years parts and workmanship. DESCRIPTION COLOUR OPTIONS Airius’ powder coated, 5mm, aluminum wall bracket is used with “Off White” the Air Pear Series, Designer Series 10, 15, 25, 45, or Retail Cool Gray 2C Series 20EC sized fans to mount to a vertical surface.
  • Page 6 To Controller OR mounted WiFi Module to a back up chain or cable (rated @ 90 kgs). Airius Air Circulation & Destratification Fan LEASH ANCHOR POINT 10-32 X 1/4 T-25 TORX PAN HEAD...
  • Page 7 (single phase) 300 VAC Rated Cord Intake Furnished 2m Airius Wall Bracket (Optional extra) Units can be attached using bolts, Chemsets or Dyna Bolts Leash Anchor Point (Not supplied) The leash anchor point acts as an additional safety point when installed.
  • Page 8 Product Information & Installation Guide AIR PEAR SERIES - Model 25/EC PEARLINK Reduce installation cost & control your Airius fan system over 2.4Ghz WiFi DISTRIBUTED COMFORT FEATURES The PearLink control system offers total fan control from a Interface is web-based (Chrome/Firefox), iOS, or Android »...
  • Page 9 Housing: PC/ABS, Off white (cool gray 2c) Mounting: Factory installed at time of ordering. Power Consumption Idle: 16mA TX/RX: 200mA AIRIUS FAN SYSTEM Wi-Fi Characteristics 802.11b/g/n 2.4 GHz TX Power 18 dBm @ 1DSSS RX Sensitivity -96 dBm @ 1 DSSS Range 100 meters Sensors &...
  • Page 10: Account Creation

    This is your command-and-control portal for the Airius fans at your facility. You can use the web based dashboard or the the Airius PearLink mobile app, available for both iOS and Android, to operate fans to fully control the air movement in a room.
  • Page 11: Provisioning Devices

    1.5-1.8 mts A.F.F. Preferably next to your existing thermostat. Open the Airius App and enter your email address and password to log in. You are now ready toprovision your devices. Note: the screen shots are from an Android device and might vary slightly for iOS devices.
  • Page 12 Review the information and select Select, “Add new device and apply most recent profile” > Follow the fan is installed the correct fan model from the drop down menu same steps for each device +61 (2) 6608 2736 info@airius.com.au www.airius.com.au...
  • Page 13: Device Control

    “Create group. You now have the ability to new group” button. control the fan speed of all devices within that group as well as on/off. +61 (2) 6608 2736 info@airius.com.au www.airius.com.au...
  • Page 14: Network Migration

    Under the individual device view, Under “Actions” select At this screen, you can enter the “Reconfigure” select the “i” icon then the gear network name and/or password icon in the upper right portion of changes. the app. +61 (2) 6608 2736 info@airius.com.au www.airius.com.au...
  • Page 15 Yellow (0-10 VDC) range of Blue (Ground) Blue Blue Blue Yellow Yellow Yellow White White White Fan 1 Fan 2 Fan 3 Tachometer PWM 1 Pulse = 1 Revolution +61 (2) 6608 2736 info@airius.com.au www.airius.com.au...
  • Page 16 3) Install the front panel as shown in the following diagram CAUTION Electrical installations should only be carried out by qualifi ed personnel only. Follow safety measures to avoid electric shock. PC/ABS 3164849 CONFORMS TO UL Standard 507 +61 (2) 6608 2736 info@airius.com.au www.airius.com.au...
  • Page 17: Specifications

    25mm SPECIFICATIONS CONTROLLER DESCRIPTION Operating voltage 24V DC ONLY (By Others) Overview The Airius Touch Screen Controller is a programmable Mounting Surface mount backbox option room controller ideal for managing Airius EC fans. Display 3.5” Resistive touch-screen The unit has no on-board inputs & outputs, but is...
  • Page 18 Product Information & Installation Guide AIR PEAR SERIES - Model 25/EC INPUT OUTPUT MODULE FOR AIRIUS TOUCH SCREEN CONTROLLER Fire Alarm Connection (By Others): UI1 Compact Modbus RTU input/output module for the Airius room controller Indoor Secondary Temperature Sensor Real-time clock Connection: U16...
  • Page 19 Universal Inputs 8 inputs are provided, confi gurable as below: Pt1000 0-19 VDC Voltage Free Contact In 1 In 2 In 3 In 4 In 5 In 6 In 7 In 8 +61 (2) 6608 2736 info@airius.com.au www.airius.com.au...
  • Page 20 RS485 A+ B- S RS485 9 10 11 12 13 14 15 16 17 230VAC AO5/DI9 AO6/DI10 Please note: Up to 10 fans (subject to fan type) can be connected to one input channel. +61 (2) 6608 2736 info@airius.com.au www.airius.com.au...
  • Page 21 AP-25/EC-230V Product Information & Installation Guide AIR PEAR SERIES - Model 25/EC AIRIUS TOUCH SCREEN CONTROLLER WITH FIRE ALARM INPUT (BY OTHERS) AND EXT TEMP SENSOR - 4 FANS BLUE EC Fan YELLOW BLUE EC Fan YELLOW BLUE EC Fan...
  • Page 22 AP-25/EC-230V Product Information & Installation Guide AIR PEAR SERIES - Model 25/EC AIRIUS TOUCH SCREEN CONTROLLER WITH FIRE ALARM INPUT (BY OTHERS) AND EXT TEMP SENSOR - 8 FANS BLUE BLUE EC Fan YELLOW EC Fan YELLOW BLUE BLUE EC Fan...
  • Page 23 Tighten captive top screw with small screw-driver. When removing display part Make sure to untighten the top fi xing screw • Pull only from the top, with two fi ngers on the sides • • Do not apply excessive force +61 (2) 6608 2736 info@airius.com.au www.airius.com.au...
  • Page 24: Installation Tips

    AP-25/EC-230V Product Information & Installation Guide AIR PEAR SERIES - Model 25/EC INSTALLATION TIPS 0.5 m 1.5 m +61 (2) 6608 2736 info@airius.com.au www.airius.com.au...
  • Page 25 Airius (Oceania) Pty Ltd P.O. Box 1812, Byron Bay, NSW 2481 +61 (2) 6608 2736 www.airius.com.au...