Toshiba MMD-AP0721HP-UL1 Service Manual page 91

Table of Contents

Advertisement

Part name
No.
1. Detachment
Sensor TA
1) Perform 1 of ① and 1 of 7 .
2) Remove the connector of the wires of TA sensor from
the control P.C. board.
3) Pinch the lock of the TA sensor holder from the outside
of the electrical parts box and push it into the inside of
the electrical parts box.
2. Attachment
1)
Attach the TA sensor to the original position.
2) Attach the wires of TA sensor in the holder as
before.
3) Attach the electrical parts box as before.
1. Detachment
Reactor
13
1) Perform 1 of ① and 1 of 7 .
2) Remove the connector of the wires of the reactor
from the fan control P.C. board.
3) Remove the screws fixing the reactor cover. Slide
the reactor cover to the arrow direction and
remove.
4) Remove the screws fixing the reactor.
5) Remove the reactor from the reactor cover.
2. Attachment
1) Attach the reactor to the reactor cover.
2) Attach the reactor cover as before.
3) Attach the wires of the reactor in the holder as
before.
NOTE
After assembling, check if that there is no abnormal sound,
vibration, or puncture.
Check the exchange point when you have a problem.
Procedure
- 91 -
Remarks
TA sensor
CN104
Electrical parts
TA sensor holder
box
CN511
CN510
Screw
Reactor
Reactor cover
screws
Reactor assembly