Toshiba MMD-AP0721HP-UL1 Service Manual page 68

Table of Contents

Advertisement

Check code
Outdoor 7-segment display
Main
remote
Check
Sub-code
control
code
A3-IPDU
Fan-IPDU
1
2
1
2
01
02
03
08
09
0A
0B
L29
L29
Detected indoor address
L30
L30
L31
P01
P03
P03
Location
of
detection
Trouble in No.
I/F
A3-IPDU
Fan-IPDU
of IPDUs
1
2
1
2
10
11
12
13
18
19
1A
1B
Circle (O): IPDU trouble
Indoor
External
unit
interlock of
indoor unit
I/F
Extended IC
trouble
Indoor
Indoor fan
trouble
unit
I/F
Discharge
temperature
TD1 trouble
Description
System status
All stop
Insufficient number of IPDUs
are detected when power is
turned on.
Stop of
• Signal is present at
external trouble input
corresponding
unit
terminal (CN80) for 1
minute.
Continued
There is part failure in P.C.
operation
board (I/F).
Stop of
corresponding
unit
All stop
Discharge temperature
(TD1) exceeds
239°F(115°C)
- 68 -
Trouble detection
Check items (locations)
condition(s)
• Check model setting of
P.C. board for servicing
outdoor I/F P.C. board.
• Check connection of UART
communication connector.
• Check A3-IPDU, fan IPDU,
and I/F P.C. board for
defect.
When external device is
connected to CN80
connector:
1) Check for defect in
external device.
2) Check for defect in indoor
P.C. board.
When external device is not
connected to CN80
connector:
1) Check for defect in indoor
P.C. board.
Check outdoor P.C. board
(I/F).
• Check the lock of fan motor
(AC fan).
• Check wiring.
• Check outdoor service
valves (gas side, liquid
side) to confirm full
opening.
• Check outdoor PMVs
(PMV1, 3) for clogging.
• Check resistance
characteristics of TD1
sensor.
• Check for insufficiency in
refrigerant quantity.
• Check for defect in 4-way
valve.
• Check for leakage of
SV4 circuit.
• Check SV4 circuit (wiring
or installation trouble
in SV41 or SV42).