Scotsman ND650 Service Manual page 16

Scotsman nd650 ice machine: user guide
Table of Contents

Advertisement

ND650
OPERATION: Refrigeration
Beginning at the compressor, the refrigerant 502 is
compressed into a high temperature gas. The
discharge line directs this gas to the condenser. At
the condenser (air or water cooled) the gas is
cooled by either air or water and it then condenses
into a liquid. This high pressure liquid then goes
through the liquid line to the expansion valve. The
thermostatic expansion valve meters liquid
refrigerant into the evaporator, the volume of liquid
refrigerant depending upon the temperature of the
evaporator; warmer evaporators get more
refrigerant and colder evaporators get less.
At the evaporator, the refrigerant enters an area of
relatively low pressure, where it can easily "boil
off" or evaporate. As it evaporates, it absorbs heat
LIQUID LINE
CONDENSER
REFRIGERATION
SCHEMATIC
DISCHARGE
HIGH
PRESSURE
CUT OUT
March, 1989
from the evaporator and whatever is in contact
with it (such as the water inside it). After the
evaporator, the refrigerant, now a low pressure
vapor, goes through the suction line back to
compressor, where the cycle is repeated.