MAINTENANCE: Air Cooled
Clean or replace the air filter.
Clean the air cooled condenser.
Air flow on this model is from front to back, so the
inside of the machine will have to be available to
clean the air cooled condenser. Use a vacuum
cleaner or coil cleaner if needed. Do NOT use a
wire brush.
A. Disconnect electrical power, and remove the
filter. The filter may be cleaned or replaced.
B. Clean the condenser: the condenser may
appear to be clean on the surface, but it can still be
clogged internally. Check with a flash light from the
front to see if light can be seen though the
condenser fins. Reverse to reassemble.
Electrical shock hazard.
Electrical shock can cause
personal injury.
Disconnect power before
beginning to service
components.
NME954 & FME1204
REMOVE TWO SCREWS & UNPLUG FAN MOTORS.
PULL FAN MOTOR ASSEMBLY UP AND
TO THE RIGHT TO REMOVE
May 2001
Page 19