NME950 & FME1200
MAINTENANCE: Air Cooled
5. Clean the air cooled condenser.
1. REMOVE TOP PANEL
2. REMOVE TWO SCREWS & UNPLUG FAN MOTORS.
Electrical shock hazard.
Electrical shock can cause
personal injury.
Disconnect power before
beginning to service
components.
TO GAIN ACCESS TO CONDENSER SURFACE:
January 1995
The air flow on this model is from front to back, so
the inside of the machine will have to be available
to clean the air cooled condenser. Use a vacuum
cleaner or coil cleaner if needed. Do NOT use a
wire brush.
A. Disconnect electrical power, and remove the
filter. The filter may be cleaned or replaced.
B. Clean the condenser: the condenser may
appear to be clean on the surface, but it can still
be clogged internally. Check with a flash light from
the front to see if light can be seen though the
condenser fins. Reverse to reassemble.
3. PULL FAN MOTOR ASSEMBLY UP AND OUT
4. CLEAN CONDENSER FINS.