Rheem MPH 13 SEER Series Installation Instructions Manual page 16

Package heat pumps featuring earth-friendly r-410a refrigerant heat controller
Table of Contents

Advertisement

GENERAL DATA - MPH
NOMINAL SIZES 2-5 TONS [7-17.6 kW]
Model MPH - Series
Cooling Performance
1
Gross Cooling Capacity Btu [kW]
EER, SEER
2
Nominal CFM/ARI Rated CFM [L/s]
ARI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
Heating Performance (Heat Pumps)
High Temp. Btuh [kW] Rating
System Power KW / COP
Low Temp. Btuh [kW] Rating
System Power KW / COP
HSPF (Btu/Watts-hr)
Compressor
No./Type
Outdoor Sound Rating (dB)
4
Outdoor Coil - Fin Type
Tube Type
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Indoor Coil - Fin Type
Tube Type
Tube Size in. [mm]
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
Outdoor Fan - Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
No. Motors/HP
Motor RPM
Indoor Fan - Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
No. Motors
Motor HP
Motor RPM
Motor Frame Size
Filter - Type
Furnished
(NO.) Size Recommended in. [mm x mm x mm]
Refrigerant Charge Oz. [g]
Weights
Net Weight lbs. [kg]
Ship Weight lbs. [kg]
NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity
is net and includes the effect of fan motor heat. Units are suitable for operation in CFM range shown in airflow tables. Units are certified in accordance with the Unitary Air
Conditioner Equipment certification program, which is based on ARI Standard 210/240 or 360.
2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Heating Performance is rated at 47° F ambient, 70° F entering dry bulb for High Temp rating and 17° F ambient, 70° F entering dry bulb for Low Temp rating. Performance
ratings do include the effect of fan motor heat.
4. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270.
16
G48A-1K-00
49,500 [14.5]
11/13
1600/1550 [755/731]
47,500 [13.92]
35,900 [10.52]
11,600 [3.4]
4.32
3
46,000 [13.48]
3.92/3.44
25,600 [7.5]
3.56/2.14
7.7
1/Copeland Scroll
78
Louvered
Rifled
0.375 [9.5]
16.54 [1.54]
1 / 22 [9]
TX Valves
Louvered
Rifled
0.375 [9.5]
5.78 [0.54]
3 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
4200 [1982]
1 at 1/3 HP
1075
FC Centrifugal
1/11x9 [279.4x228.6]
Direct/2
1
3/4
1075
48
Field Supplied
No
(1)1x24x24 [25x610x610]
120 [3402]
429 [195]
455 [206]
G60A-1K-00
62,000 [18.17]
11/13
2000/1900 [944/897]
59,000 [17.29]
44,500 [13.04]
14,500 [4.25]
5.36
61,000 [17.87]
5.15/3.52
34,400 [10.08]
4.64/2.18
7.7
1/Copeland Scroll
78
Louvered
Rifled
0.375 [9.5]
16.54 [1.54]
2 / 18 [7]
TX Valves
Louvered
Rifled
0.375 [9.5]
5.78 [0.54]
4 / 13 [5]
TX Valves
1/1 [25.4]
Propeller
1/24 [609.6]
Direct/1
4000 [1888]
1 at 1/3 HP
1075
FC Centrifugal
1/11x9 [279.4x228.6]
Direct/2
1
3/4
1075
48
Field Supplied
No
(1)1x24x24 [25x610x610]
193 [5472]
481 [218]
507 [230]