Pre-Installation (continued)
WIRING CONNECTION REQUIREMENTS
Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction.
OBSERVE ALL GOVERNING CODES AND ORDINANCES AND WARNINGS
□ Electrical grounding is required for this range hood. Check with
a qualified electrician if you are not sure whether the range
hood is properly grounded.
□ Failure to follow electrical requirements may result in a fire.
□ A fuse in the neutral or grounding circuit could result in
electrical shock.
□ If hot/cold water pipe is interrupted by plastic/nonmetallic
gaskets or other materials, DO NOT use for grounding.
□ DO NOT GROUND TO A GAS PIPE.
IMPORTANT:
It's the customer's responsibility to contact a quali-
fied electrical installer and assure that the electrical installation is
adequate and complies with the National Electrical Code, or CSA
standards, as well as all local codes and ordinances.
□ Save installation instructions for electrical inspector's use.
□ If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine if the
ground path is adequate.
□ DO NOT use an extension cord or adapter plug with this
appliance.
□ The range hood must be connected with copper wire only.
□ The range hood should be connected directly to the junction (or
circuit breaker) box through flexible, armoured or nonmetallic
sheathed copper cable. Allow some slack in the cable so the
appliance can be moved if it is necessary.
□ A UL listed or CSA approved conduit connector must be
provided at each end of the power supply cable (at the range
hood and at the junction box).
□ When making the electrical connection, cut a 1-1/4 in. (3.2 cm)
hole in the wall. A hole cut through wood must be sanded until
smooth. A hole through metal must have a grommet.
□ When cutting or drilling into the wall or ceilling, do not damage
electrical wiring and other hidden utilities.
□ Wire size must conform to all local codes and ordinances.
The latest edition requirements of the National Electrical Code
ANSI/ NFPA 70, or the latest edition CSA Standards C22.1-94,
Canadian Electrical Code Part 1 and C22.2 No. 0-M91.
DANGER:
Risk of electrical shock. This range hood must be
properly grounded.
DANGER:
Turn off the power circuit breaker or the power
switch on the junction box before installing or servicing this unit.
Touching circuitry inside the range hood while it is energized
will result in death or serious injury.
DANGER:
All electrical wiring must be properly installed,
insulated, and grounded. Improper insulation and grounding will
result in deadly electrical shock.
NOTE: Temporarily wire the range hood to test it for proper
operation. If the range hood does not operate correctly, do not
proceed with the installation.
□ Disconnect power.
□ Run 3 wires - black, white, and green - according to the
National Electrical Code and local codes and ordinances, in 1⁄2
in. conduit from the service panel to the junction box.
WARNING:
Electrically ground the blower. Use copper wire.
Connect ground wire to green ground screw in terminal box.
Failure to do so can result in death, fire or electrical shock.
□ Use UL listed wire connectors and connect white wires
together.
□ Use UL listed wire connectors and connect black wires
together.
□ Connect green (or bare) ground wire from power supply to
green ground screw in terminal box and securely tighten.
□ Close and secure the junction box cover with the screw
prevously removed.
□ Turn the power on, and ensure that the lights and the fan are
operating correctly.
□ Once you have tested the electrical connection, disconnect the
power supply cable and wires from the electrical source before
proceeding with the rest of the installation.
3
1
2
9
Please contact 1-855-847-7264 for further assistance.
1. White wires.
2. Black wires.
3. UL listed wire connector.
4. Green (or bare) ground
wire.
5. Home power supply cable.
6. UL listed or CSA approved
1/2 in. strain relief.
7. Green ground screw.